摘要
根据国内在役核电厂运行反馈,主系统测温旁路安全1级手动截止阀的阀体阀盖若采用分体式锻造,则阀体与阀盖连接处的唇边焊会发生泄漏或存在泄漏风险,因此需选用阀体阀盖一体化铸造的截止阀进行替代。为了判断一体化铸造阀门的阻力特性能否满足系统的阻力要求,使用CFD软件CFX对一体化阀门的流阻特性进行数值模拟计算,分析所采用替换阀门对测温旁路系统流阻要求的适应性。分析结果表示一体化阀门的流阻特性能满足测温旁路系统要求。
Split forging technology is applied in the manufacture of the globe valve used in the bypass temperature measurement of the reactor coolant system(RCS)in some nuclear power plants.This technology,however,leads to the leakage risk at the lips weld on the connecting point between the deck and body of the valve.Thus,using the integrated-casting valve instead is necessary and moreover,this type of valve should satisfy the requirement of flow resistance characteristic.This work focuses on the analysis for the flow resistance characteristic of the integrated-casting valve based on the numerical CFX simulation.The result shows that the requirement of the flow resistance characteristic of this valve type can be satisfied for the bypass temperature measurement.
作者
张文其
曹思民
叶竹
沈云海
王保平
ZHANG Wen-qi;CAO Si-min;YE ZHU;SHEN Yun-hai;WANG Bao-ping(Science and Technology on Reactor System Design Technology Laboratory,Chengdu Sichuan 610213 ,China)
出处
《科技视界》
2017年第23期86-87,共2页
Science & Technology Vision
关键词
测温旁路
阀门
数值模拟
流阻特性
Resistance temperature detector by pass manifold system
Valves
Numerical simulation
Flow resistance characteristics