摘要
介绍了地下机械式停车库发生火灾的原因及火灾的危险性,针对停车库的自动喷水灭火系统设计要点进行了深入分析,最后得出在地下车库的各个停车位置安装自动喷水灭火系统喷头,对喷头的选用、作用面积系统流量以及水力进行精密的计算,才能在火灾出现以后,充分发挥自动喷水灭火系统的作用,达到安全灭火的目的。
This paper introduced the hazard reason of underground mechanical parking garage fire and fire,automatic sprinkler for garage fire extinguishing system design are analyzed,finally in the underground garage of each parking position installation of sprinkler system nozzle,selection of nozzle flow and hydraulic system action area of precise calculation,in order to fire after the appearance of fully automatic sprinkler system,fire safety reached to the conclusion.
作者
姚学军
Yao Xuejun(Shanxi Chemical Design Institutey Taiyuan 030024,China)
出处
《山西建筑》
2017年第30期126-127,共2页