期刊文献+

Surface-Based Morphometry of Human Brain: Intra-Individual Comparison Between 3T and 7T High Resolution Structural MR Imaging

基于表面的形态测量学:3T与7T高分辨磁共振结构成像受试者内比较(英文)
下载PDF
导出
摘要 Objective High resolution structural MR imaging can reveal structural characteristics of cerebral cortex and provide an insight into normal brain development and neuropsychological diseases. The aim of this study was to compare cortical structural characteristics of normal human brain between 3T and 7T MRI systems using surface-based morphometry based on high resolution structural MR imaging.Methods Twelve healthy volunteers were scanned by both 3T with 3D T1-weighted fast spoiled gradient recalled echo (3D T1-FSPGR) sequence and 7T with 3D T1-weighted magnetization-prepared rapid gradient echo (3D T1-MPRAGE) sequence. MRI data were processed with FreeSurfer. The cortical thickness,white and gray matter surface area, convexity, and curvature from data of 3T and 7T were measured and compared by paired t-test.Results Measurements of mean cortical thickness, total white matter surface area and gray matter surface area of 3T were larger than those of 7T (left hemisphere: P=0.000, 0.006, 0.020 respectively; right hemisphere: P=0.000, 0.000, 0.000 respectively). Surface-based morphometry over the whole brain demonstrated both reduced and increased measurements of cortical thickness, white and gray surface area,convexity, and curvature at 7T compared to 3T.Conclusions Inconsistency of brain structural attribute between 3T and 7T was confirmed, and researchers should be cautious about data when using ultrahigh field MR system to investigate brain structural changes. Objective High resolution structural MR imaging can reveal structural characteristics of cerebral cortex and provide an insight into normal brain development and neuropsychological diseases. The aim of this study was to compare cortical structural characteristics of normal human brain between 3T and 7T MRI systems using surface-based morphometry based on high resolution structural MR imaging. Methods Twelve healthy volunteers were scanned by both 3T with 3D T1-weighted fast spoiled gradient recalled echo(3D T1-FSPGR) sequence and 7T with 3D T1-weighted magnetization-prepared rapid gradient echo(3D T1-MPRAGE) sequence. MRI data were processed with Free Surfer. The cortical thickness, white and gray matter surface area, convexity, and curvature from data of 3T and 7T were measured and compared by paired t-test. Results Measurements of mean cortical thickness, total white matter surface area and gray matter surface area of 3T were larger than those of 7T(left hemisphere: P=0.000, 0.006, 0.020 respectively; right hemisphere: P=0.000, 0.000, 0.000 respectively). Surface-based morphometry over the whole brain demonstrated both reduced and increased measurements of cortical thickness, white and gray surface area, convexity, and curvature at 7T compared to 3T. Conclusions Inconsistency of brain structural attribute between 3T and 7T was confirmed, and researchers should be cautious about data when using ultrahigh field MR system to investigate brain structural changes.
出处 《Chinese Medical Sciences Journal》 CAS CSCD 2017年第4期226-231,共6页 中国医学科学杂志(英文版)
基金 Fund supported by National Natural Science Foundation of China (81171319), the Foundation for Medical and Health Sci & Tech Innovation Project of Sanya (2016YW37) and the Special Financial Grant from China Postdoctoral Science Foundation (2014T70960).
关键词 MRI ultra high field MORPHOMETRY BRAIN CORTEX MRI ultra high field morphometry brain cortex
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部