期刊文献+

Breakdown characteristics of CF4 and CF4/N2 hybrid gas in refrigeration temperature range 被引量:1

Breakdown characteristics of CF_4 and CF_4/N_2 hybrid gas in refrigeration temperature range
下载PDF
导出
摘要 Common insulation gas cannot normally work in refrigeration temperature range(153-243 K), especially in extremely cold regions. To solve this problem, this essay uses cubic equation combined with two-parameter model in theorem of corresponding states to estimate dew-point of hybrid gas. The influence of temperature on mixing ratio is studied by using van der Waals equation. The result shows that the mixing ratio is stable during temperature-fall period. Insulation property of CF_4 and CF_4/N_2 in refrigeration temperature range is studied through self-designed low-temperature test system. The result shows when the density of hybrid gas is invariable, temperature changing has less influence on breakdown voltage, and when the mixing ratio is 20%, CF_4/N_2 is the greatest potential hybrid gas. Common insulation gas cannot normally work in refrigeration temperature range(153-243 K), especially in extremely cold regions. To solve this problem, this essay uses cubic equation combined with two-parameter model in theorem of corresponding states to estimate dew-point of hybrid gas. The influence of temperature on mixing ratio is studied by using van der Waals equation. The result shows that the mixing ratio is stable during temperature-fall period. Insulation property of CF_4 and CF_4/N_2 in refrigeration temperature range is studied through self-designed low-temperature test system. The result shows when the density of hybrid gas is invariable, temperature changing has less influence on breakdown voltage, and when the mixing ratio is 20%, CF_4/N_2 is the greatest potential hybrid gas.
作者 侯孟希 李卫国 袁创业 阳以歆 欧阳洁 HOU Meng-xi;LI Wei-guo;YUAN Chuang-ye;YANG Yi-xin;OUYANG Jie
出处 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第4期861-865,共5页 中南大学学报(英文版)
基金 Project(51277063)supported by the National Natural Science Foundation of China
关键词 dew-point REFRIGERATION temperature RANGE CF4 gas INSULATION dew-point refrigeration temperature range CF_4 gas insulation
  • 相关文献

参考文献7

二级参考文献105

  • 1肖登明,邱毓昌.SF_6/N_2和SF_6/CO_2的绝缘特性及其比较[J].高电压技术,1995,21(1):16-18. 被引量:21
  • 2王湘汉,汪沨,邱毓昌.SF_6/N_2混合气体流注放电二维动力学模型的计算机仿真[J].绝缘材料,2007,40(4):70-73. 被引量:8
  • 3F W Blodgett.Properties of octafluorocyclobutane,a dielectric gas,ALEE,1959:63-66.
  • 4D R James,L G Christophorou,R Y Pai,et al.Dielectric strength of new gases and gas mixtures,gaseous dielectrics 1,1978:224-226.
  • 5O Yamamoto,T Takuma,S Hamada,et al.Applying a gas mixture containing c-C4 F8 as an insulation medium.IEEE transactions on Dielectris and Electrical insulation,2001,8(6):1075-1081.
  • 6L G Christophorou,J K Olthoff,D S Green.Gases for Electrical Insulation and Arc Interrupion:Possible Present and Future Alternatives to Pure SF6.NIST Technical Note 1425.
  • 7Christophorou L G, Olthoff J K, Green D S. A search for possible universal-applications' gas mixtures[C]. Proc. Eighth Intl. Symp. of Gaseous Dielectrics Ⅷ, publ. Kluwer Academic/Plenum Press, NY, 1998: 361-367.
  • 8Yamamoto O, Takuma T, Hamada S, et al. Applying a gas mixture containing c-C4F8 as an insulation medium[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2001, 8(6): 1075-1081.
  • 9Wen C, Wetzer J M. Time-resolved avalanche current waveforms in octafluorocyclobutane[J]. IEEE Transactions on Electrical Insulation, 1989, 24 (1): 143-150
  • 10J de Urquijo, Basurto E. Electron attachment, ionization and drift in c-C4F8 [J]. J. Phys. D: Appl. Phys, 2001, 34 (9): 1352-1354.