期刊文献+

普通照明用自镇流LED灯的频闪问题分析 被引量:3

Analysis of Flicker Problem of Self-Ballasted LED Lamps for General Lighting Services
下载PDF
导出
摘要 通过采用两份国际上主流的频闪问题技术规范中规定的测试项目,对80批次从市场购买及从企业取回的普通照明用自镇流LED灯样品进行了检测。对目前市场上该产品的频闪问题现状进行了一次摸底,并从技术规范项目的设定原理以及产品的检测结果来分析两份技术规范的特点,归纳了其统一性及区别。 We tested80batches self-ballasted LED lamps for general lighting services we bought or obtained from manufactories,adopting the test items in2international mainstream technology specification of flicker.We were trying to find out the existing status of flicker problems on the market.In this paper,we analyze the two specifications to conclude their unity and differences from the principles and the test results.
作者 薛晓晓 陈萍 王建 XUE Xiaoxiao;CHEN Ping;WANG Jian(Zhejiang Provincial Testing Institute of Electronic Information Products,Hangzhou 310007,China)
出处 《照明工程学报》 2017年第6期66-69,共4页 China Illuminating Engineering Journal
关键词 照明 自镇流LED灯 频闪 闪烁百分比 SVM指数 self-ballasted LED lamps for general lighting services flicker percent flicker NM Pst SVM