摘要 介绍了8万m^3转炉煤气柜的基本结构,重点说明了转气柜侧板和底板的厚度及材质;对柜底板和侧板腐蚀情况进行了检查,分析总结了原因,提出了对策并付诸实施,取得了良好效果。 The basic structure of the80000m3converter gasholder is introduced,with the focus on the thickness and material of the side plate and bottom plate.Corrosion in the bottom plate and side plate of the gasholder were inspected,the causes of the problem were analyzed and countermeasures put forward and implemented,which has brought favorable effect.
作者 王玉兴 孙德银 韩其福 WANG Yuxing;SUN Deyin;HAN Qifu(Shougang Jingtang United Iron and Steel Co., Ltd., Tangshan, Hebei 063000, China)
出处 《冶金动力》 2018年第4期24-26,共3页 Metallurgical Power
关键词 转炉煤气 煤气柜 腐蚀 抽真空 LDG gasholder corrosion vacuuming