摘要 采用模拟试验的方式研究了冷却塔淋雨噪声特性随着淋雨高度、淋雨面积和淋雨密度变化的规律。结果表明,淋雨的噪音频段集中在中高音频,且其频谱特性不随上述条件变化而改变;淋雨噪声随淋雨密度和淋雨面积增大有明显变化,淋雨高度变化对淋雨噪声的影响几乎可以忽略。研究结果可供冷却塔淋雨噪声的预报和治理参考。 This experiment studies the rules of the characteristics of cooling tower water drenching noise with the change of drenching water height,area and density.The results show that,the water drenching noise mainly focuses on the middle and high frequency and the spectrum characteristics doesn’t change with the change of the above mentioned conditions,the water drenching noise changes obviously with the increase of density and area,but change little with that of height.The research results can provide references for the forecast and control of cooling tower water drenching noise.
作者 解明远 赵顺安 宋小军 XIE Mingyuan;ZHAO Shun’an;SONG Xiaojun(Department of Hydraulics,China Institute of Water Resources and Hydropower Research Beijing 100038)
出处 《工业安全与环保》 2018年第3期65-67,共3页 Industrial Safety and Environmental Protection
关键词 冷却塔噪声 淋雨密度 淋雨面积 淋雨高度 noise of cooling tower water drenching density water drenching area water drenching height
  • 相关文献

参考文献6

二级参考文献17

  • 1吕玉恒,郁慧琴,黄平,王震洲,潘捷,张明发,康骏.特大型双曲线自然通风冷却塔噪声治理设计及效果[J].工程建设与设计,2004(10):9-11. 被引量:2
  • 2赵振国.冷却塔[M].北京:中国水利水电出版社,1996.1-101.
  • 3.GB/T 14623—93.城市区域环境噪声测量方法[S].,..
  • 4.GB 3096---93.城市区域环境噪声标准[S].,..
  • 5倪季良.冷却塔落水消能降噪装置[R].西安:西北电力设计院,2001..
  • 6王建荣.火电厂冷却塔噪声防治措施分析与探讨[R].南京:江苏省电力设计院,2000..
  • 7[日]公害防止技术法规编委会(卢贤昭译).公害防止技术噪声篇[M].北京:化学工业出版社,1988..
  • 8GB12348-2008工业企业厂界环境噪声排放标准[S].
  • 9GB22337-2008,社会生活环境噪声排放标准[S].
  • 10DLS000—2000.火力发电厂设计技术规程[S].[S].,..

共引文献28

同被引文献29

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部