电机绝缘系统在高频冲击下局部放电试验研究 被引量:8

Study on the Test of Partial Discharge Under High Frequency Impulse Voltage for Motor Insulation System
下载PDF
导出
摘要 高频冲击局部放电(PD)测试可以有效的检测电机绝缘系统的绝缘状态。根据传感器的不同,电机绝缘系统在高频冲击下PD测试方法主要有两种:高频电流传感器法和超高频天线法。试验表明:在高频冲击电压下,PD主要发生在冲击的上升沿和下降沿,在同一放电电压下,上升沿和下降沿的PD幅值较大;在风力发电机定子绝缘系统鉴别试验中,随着老化试验的进行,线圈的PD起始电压总体呈下降趋势。通过鉴别试验,可以确定绝缘系统的冲击电压绝缘等级及类型。 The measurement of partial discharge(PD)under high frequency impulse voltage may be effective to check the insulation condition of the motor insulation system.Depending on the sensor,there were two methods of detecting PD under high frequency voltage for the motor insulation system:High\|frequency Current Transducer and ultrahigh frequency antenna.The PD activities mainly occur in both pulse rising edge and falling edge under the impulse voltage.The amplitudes of PD in both rising edge and falling edge were higher under the same applied voltage.In the qualification test of stator insulation system of wind turbines,the PD inception voltages of the coil were decreasing with the aging test.the impulse voltage insulation class and type of stator insulation system are determined by the qualification test.
作者 张生德 汪双灿 赵超 ZHANG Shengde;WANG Shuangcan;ZHAO Chao(Shanghai Electrical Apparatus Research Institute, Shanghai 200063, China;Shanghai Engineering Research Center of Motor System Energy Saving Co., Ltd., Shanghai 200063, China)
出处 《电机与控制应用》 2018年第2期102-105,共4页 Electric machines & control application
基金 上海张江国家自主创新示范区专项发展资金重点项目(201609-PT-C1085-002)
关键词 电机 高频冲击电压 局部放电 绝缘系统 motor high frequency impulse voltage partial discharge insulation system
  • 相关文献

参考文献2

二级参考文献40

  • 1段一雄.GIS局部放电试验研究情报综述[J].云南电力技术,1995,23(2):45-48. 被引量:4
  • 2吴广宁,刘曦,佟来生,张血琴.提取PWM脉冲下局部放电信号的sym4小波滤波器的研究[J].电工技术学报,2006,21(2):35-38. 被引量:15
  • 3吴广宁,马积勋,吴欣延,谢恒堃,陈志清,孙德琳.大型电机局部放电监测用宽频电流传感器及应用的研究[J].西安交通大学学报,1996,30(6):8-14. 被引量:14
  • 4江本邦夫 村濑洋.用表面电流传感器的GCB用便携式诊断装置的开发[J].电学论B,1998,118(6):666-666.
  • 5IEC-270标准..[S].,..
  • 6Dakin T W, Malinaric P J. A capacitive bridge method for measuring integrated corona-charge transfer and power loss per cycle. Trans AIEE PAS, 1960,79: 648~653.
  • 7Izeki N, Tatsuta F. Three types of partial discharges in electrical insulation. Conf. Record on IEEE Intern. Symp. in El. Ins., Montreal 1984: 327~331.
  • 8Boggs S A, Stone C. Fundamental limitations in the measurement of corona and partia discharge. IEEE Trans. on EI 1982, 17 (2): 143~150.
  • 9Dakin T W, Malinaric P J. A capacitive bridge method for measuring integrated corona-charge transfer and power loss per cycle. Trans AIEE PAS 1960, 79:648~653.
  • 10Izeki N, Tatsuta F. Three types of partial discharges in electrical insulation. Conf. Record on IEEE Intern. Symp. in El. Ins., Montreal, 1984: 327~331.

共引文献274

同被引文献63

引证文献8

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部