期刊文献+

128层螺旋CT评价冠状动脉支架再狭窄的价值 被引量:1

Evaluation of Coronary Stent Restenosis by 128 Slice Spiral CT
下载PDF
导出
摘要 目的:观察128层螺旋CT评价冠状动脉支架再狭窄的价值。方法:选取于我院行经皮冠状动脉介入治疗支架植入术的患者78例,所有患者均给予C臂X线冠状动脉血管造影检查、128层螺旋CT冠状动脉扫描检查以及1.5T超导磁共振冠状动脉成像检查,比较其检查结果。结果:128层螺旋CT冠状动脉扫描成像与C臂X线血管造影检查临床结果具有一致性,数据差异明显具有统计学意义(P<0.O5)。结论:对于行经皮冠状动脉介入治疗支架植入术的患者给予128层螺旋CT冠状动脉扫描成像检查可有效判定冠状动脉支架再狭窄情况。 Objective:To observe the value of128slice spiral CT evaluation of coronary artery stent restenosis.Methods:In our hospital of the78patients underwent percutaneous coronary artery interventional therapy and stent implantation for patients in this study,all patients were given C arm X-ray coronary artery angiography,128coronary check artery spiral CT scanning and1.5T superconducting magnetic resonance coronary angiography,the sensitivity of three kinds of check detection accuracy,specificity.Results:128slice spiral CT coronary artery imaging and C arm X-ray angiography examination with clinical results there is consistency,data difference was statistically significant(P<0.O5).Conclusion:For the given scanning imaging of128slice CT coronary angiography can effectively determine coronary artery stent restenosis in stent implantation for patients undergoing percutaneous coronary intervention.
作者 陈娟 CHEN Juan(The Affiliated Renhe Hospital of China Three Gorges University, Hubei 443001,China)
出处 《影像技术》 CAS 2018年第2期51-52,56,共3页 Image Technology
关键词 128层螺旋CT 冠状动脉支架 冠状动脉再狭窄 128 Slice Spiral CT Coronary Stent Coronary Restenosis
  • 相关文献

参考文献4

二级参考文献32

  • 1沈雳,葛均波.药物洗脱支架的应用现状和展望(英文)[J].中国组织工程研究与临床康复,2007,11(51):10404-10408. 被引量:6
  • 2刘新,李颖,杨立,赵锡海,王新疆,赵绍宏,张玉霄,蔡祖龙.64层螺旋CT评价冠状动脉支架内再狭窄的价值[J].中华放射学杂志,2006,40(8):808-811. 被引量:44
  • 3Okamura T, Serruys PW, Regar E. Three-dimensional visualization of intracoronary thrombus during stent implantation using the second generation, Fourier domain optical coherence tomography [J]. Eur Heart J,2010,31(5): 625.
  • 4Mark DB, Berman DS, Budoff MJ, et al. 2010 expert document on coronary computed tomographic angiography: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents [J]. Circulation, 2010, 121(22) : 2509-2543.
  • 5Rixe J, Rolf A, Conradi G, et al. Image quality on dual source computed tomographic cononary angioga'aphy [J ]. Eur Radiol. 2008, 94(11): 1386- 1393.
  • 6Koc O, Kivrak AS, Ozdemir K. Evaluation of small coronary artery aneurysm by 64- slice multi- detector CT coronary angiography and virtual angioscopy [J]. Anadolu Kardiyol Derg, 2008, 8(5): E32.
  • 7Okamura T, Serruys PW, Regar E. Three-dimensional visualization of intracoronary thrombus during stem implantation using the second generation ,Fourier domain optical coherence tomography [J]. Eur Heart J,2010,31 (5):625.
  • 8Escolar E, Weigold G, Fuisz A, et al. New imaging techniques for diagnosing coronary artery disease [J].CMAJ, 2006,174 (4) : 487-495.
  • 9蒲锘,蒲红,蒋瑾,陶客言.双源CT冠状动脉造影:成像质量因素分析[J].成都医学院学报,2009,4(1):14-16. 被引量:7
  • 10D.Maintz,M.C.Burg,H.Seifarth,A.C.Bunck,M.zgün,R.Fischbach,刘靖.冠状动脉多层CTA评价冠状动脉支架的最新进展:双源CT体外评估29种不同支架[J].国际医学放射学杂志,2009,32(2):194-195. 被引量:21

共引文献23

同被引文献7

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部