Design of detector to monitor the Bragg peak location of carbon ions by means of prompt γ-ray measurements with Geant4

Design of detector to monitor the Bragg peak location of carbon ions by means of prompt γ-ray measurements with Geant4
下载PDF
导出
摘要 Real-time monitoring of the Bragg peak location of carbon ions is urgently required for the quality control of hadron therapy. In this study, we design an annular detector to monitor the Bragg peak location of carbon ions with Geant4 simulation. This 360° surrounding structure has a high detection efficiency for the small-dose situation. The detector consists of a multilayered collimator system and an Na I scintillator for prompt gamma counting. The multilayered collimator includes a lead layer to prevent unwanted gammas and the paraffin and boron carbide layers to moderate and capture fast neutrons. An inclination of the detector further diminishes the background signal caused by neutrons. The detector, with optimized parameters, is applicable to carbon ions of different energies. In addition, the scintillator is replaced by an improved EJ301 organic liquid scintillator to discriminate gammas and neutrons. Inserting thin Fe slices into the liquid scintillator improves the energy deposition efficiency. The Bragg peak location of 200 Me V/u carbon ions can be monitored by prompt gamma detection with the improved liquid scintillator. Real-time monitoring of the Bragg peak location of carbon ions is urgently required for the quality control of hadron therapy. In this study, we design an annular detector to monitor the Bragg peak location of carbon ions with Geant4 simulation. This 360° surrounding structure has a high detection efficiency for the small-dose situation. The detector consists of a multilayered collimator system and an Na I scintillator for prompt gamma counting. The multilayered collimator includes a lead layer to prevent unwanted gammas and the paraffin and boron carbide layers to moderate and capture fast neutrons. An inclination of the detector further diminishes the background signal caused by neutrons. The detector, with optimized parameters, is applicable to carbon ions of different energies. In addition, the scintillator is replaced by an improved EJ301 organic liquid scintillator to discriminate gammas and neutrons. Inserting thin Fe slices into the liquid scintillator improves the energy deposition efficiency. The Bragg peak location of 200 Me V/u carbon ions can be monitored by prompt gamma detection with the improved liquid scintillator.
机构地区 PLAC
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第4期83-91,共9页 核技术(英文)
基金 supported by the National Natural Science Foundation of China(Nos.11375073 and U1232206)
关键词 Braggpeak Carbonion Promptc-ray GEANT4 Bragg peak Carbon ion Prompt γ-ray Geant4
  • 相关文献

参考文献1

二级参考文献17

  • 1Jakel O,Schulz-Ertner D,Karger C P,et al.Technol.Cancer Res Treat,2003,2:377-387.
  • 2Olsen D R,Bruland (φ)yvind S,Frykholm G,et al.Radiother.Oncol.,2007,83:123-132.
  • 3Char D H,Kroll S M.,Castro J.Am J Ophthalmol,1998,125:81-89.
  • 4Tsujii H,Mizoe J,Kamada T,et al.Radiother Oncol,2004,73:41-49.
  • 5Tsujii H,Kamada T,Baba M,et al.New J.Phys.,2008,10:075009 (16pp).
  • 6Agostinelli S,Allison J,Amako K,et al.Nucl.Instrum.Methods,2003,506:250-303.
  • 7Pshenichno I,Mishustin I,Greiner W.Phys.Med.Biol.,2005,50:5493-5507.
  • 8Pshenichnov I,Larionov A,Mishustin I,et al.Phys.Meal.Biol.,2007,52:7295-7312.
  • 9Fiedler F,Crespo P,Parodi K,et al.IEEE Trans.Nucl.Sci.,2006,53:2252-2259.
  • 10Jan S,Santin G,Strul D,et al.Phys.Med.Biol.,2004,49:4543-4561.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部