期刊文献+

快速测定锌矿石中的锌含量

Rapid Determination of Zinc in Zinc Ore
下载PDF
导出
摘要 高含量的锌精矿中锌的测定一般都用EDTA容量法,该方法结果稳定,矿石中的杂质含量对测定结果没有影响,但是用EDTA容量法过程繁琐,花费时间较长,不适用于测定生产流程中产生的大量的工艺样。而先用碘量法测铜的方法除去矿石中的铜,再加入铁氰化钾进行测锌的检测方法更适合生产流程。经过本公司多年来的生产实践证明:先用碘量法测铜的方法除去矿石中的铜,再加入铁氰化钾进行测锌的方法效果理想、测定过程快速、方法简便且结果准确,节约了大量的人力物力。 The determination of zinc in zinc concentrates of high content generally uses the EDTA volumetric method,The method is stable,The content of impurities in the ore has no effect on the determination results,However,this method is cumbersome and takes a long time,Not suitable for measuring a large number of process samples generated in the production process.In the method,the copper in the ore is first removed by measuring the copper by an iodometric method,and then potassium ferricyanide is added to measure the zinc.After years of our company using this method to determine a large number of samples of the company shows that the method of determination of zinc results are ideal,the method is simple and save a lot of manpower and resources.
作者 杨梅 YANG Mei(Sichuan Huili Zinc and Plumbum Co.,Ltd,Huili 615105,China)
出处 《四川有色金属》 2018年第1期31-32,45,共3页 Sichuan Nonferrous Metals
关键词 碘量法 铁氰化钾 Na2S2O3标准溶液 Iodometric method Potassiumferricyanide Standard solution of Na2S2O3
  • 相关文献

参考文献1

二级参考文献3

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史