对比了国内外有关标准对轨道客车空调新风量的规定,从车内二氧化碳允许浓度、旅客行程时间、对列车供电能力的影响等方面对轨道客车空调新风量进行了分析,并提出了按不同载客量计算轨道客车空调新风量的方法。
The specifications in relevant standards in China and abroad on fresh air volume of air-conditioning on rail passenger cars are compared.The fresh air volume of air-conditioning is analyzed from such aspects as permissible concentration of carbon dioxide inside car,passenger travel time and effect on power supply capacity for trains.And the method to calculate fresh air volume of air-conditioning on rail passenger cars on the basis of different passenger seating capacities is put forward.
出处
《铁道车辆》
2018年第3期1-4,共4页
Rolling Stock
关键词
轨道客车
空调系统
新风量
分析
rail passenger car
air-conditioning system
fresh air volume
analysis