摘要
说明了浮充电方式用于后备电源的特点,以及VRLA电池和开口富液式电池在浮充电状态下的区别。并且,从反应原理上说明了传统的浮充电方式并不适合VRLA电池特性,以及导致VRLA电池浮充寿命短的根本原因。解释了间歇充电方式比浮充电方式更适合于后备用VRLA电池的原因,以及间歇充电方式对于提升VRLA电池在后备应用中可用性的优势。
The characteristics of floating charging mode and the differences between VRLA batteries and flooded batteries under the floating charging state are illustrated.From the principle of reaction,the primary causes of that the traditional floating charging mode is not suitable for VRLA batteries and lead to the short floating charging life are explained.And also,why intermittent charging method is more suitable for the VRLA battery and intermittent charging method advantages for VRLA battery is explained.
作者
杨勇
赵俊
陈伦维
YANG Yong;ZHAO Jun;CHEN Lunwei(Shenzhen BSB Power Company Limited,Shenzhen Guangdong 518057,China)
出处
《蓄电池》
2018年第2期82-86,共5页
Chinese LABAT Man
关键词
VRLA电池
富液式电池
浮充充电
间歇充电
后备电源
自放电
VRLA battery
flooded battery
floating charging
intermittent charging
standby power supplies