期刊文献+

基于Rhino的计算机辅助设计软件的3D打印应用 被引量:4

Application of Rhino based computer aided design software in 3D printing
下载PDF
导出
摘要 传统的3D打印存在兼容性差的问题,在打印精细工件、弹性工件时存在一定的磨损缺陷。为了优化3D打印性能提出并设计基于Rhino的计算机辅助设计软件。根据计算机辅助设计软件的用途,设计Rhino插件基本参数,通过Rhino插件多点添加数据,将Rhino技术插件导入计算机辅助设计软件,优化其渲染功能,完成计算机辅助软件的设计。实验数据表明,设计的基于Rhino的计算机辅助设计软件能够对高精度工件、弹性工件进行高精度3D打印,可优化3D打印效果,具有一定的实用性。 The traditional 3D printing has the problem of poor compatibility,and some wear defects exist when fine work-piece and elastic workpiece are printed.To optimize the performance of 3D printing,a computer aided design software based on Rhino is proposed and designed.According to the application of computer aided design software,the basic parameters of Rhino plug-in are designed.By using the Rhino plug-in for data multi-point addition,the Rhino technology plug-in is imported to the computer aided design software to optimize its rendering function and complete the design of computer aided software.The exper-imental data shows that the designed Rhino based computer-aided design software can perform high-precision 3D printing for high-precision workpiece and elastic workpiece,optimize the 3D printing effect,and has a certain practicality.
作者 李庆君 LI Qingjun(Taihu University of Wuxi,Wuxi 214064,China)
机构地区 无锡太湖学院
出处 《现代电子技术》 北大核心 2018年第8期109-112,共4页 Modern Electronics Technique
基金 江苏自然科学基金(BK20140019) 江苏省教育学会"十二五"规划课题(SJ-1315)~~
关键词 Rhino技术 计算机辅助设计软件 软件设计 3D打印 插件 参数设置 Rhino technology computer aided design software software design 3D printing plug-in parameter setting
  • 相关文献

参考文献5

二级参考文献56

  • 1刘桂瑛,王韬.医疗顾客满意度指数测评理论模型研究[J].中国卫生质量管理,2005,12(4):30-33. 被引量:21
  • 2江涛,罗军,张吉翔.骨髓间充质干细胞移植在股骨头坏死修复中的应用[J].中国组织工程研究与临床康复,2007,11(24):4798-4801. 被引量:2
  • 3Bourne RB, Chesworth BM, Davis AM, et aL Patient satisl~wtion after total knee arlhrol~lasty: who is satisfied and who is not?[J ]. Clin Orthop Relat Res, 21110. 468(1): 57-63. DOh 10. 1007/ s11999-009-1119-9.
  • 4Mahaluxmivala J, Bankes MJ, Nieolai It), et al. 'File ef|~('/ of surge,,n experience oll con)portent positioning in 673 Press Fit Condylar i)os- terior eruciate-saerifieing total knee arthroplasties[J ]. J Arlhr()l)lasty. 2001, 16(5): 635-640.
  • 5Choong PF. Do~sey MM. Sl~,ney alignment resuh in better function conventional and computer-assisted Arlhroplasly, 2009, 24(4): JD. Does accurate anal~mtieal and quality of life? Comparing total knee arthroplasty[J] ~ J 560-569. DOh 10. 1016/j. arth. 2008.02. 018.
  • 6Ng VY, DeClaire JH, Berend KR, et al. hnproved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA[J] . Clin Orthop Relat Res, 2012, 470(1): 99-107. DOI: 10.1007/s11999-011-1996-6.
  • 7Krishnan SP, Dawood A, Richards R, et al. A review of rapid pro- totyped surgical guides for patient-specific total knee replacement[J]. J Bone JointSurgBr, 2012, 94 (11): 1457-1461. DOI: 10.1302/ 0301-620X. 94B11. 29350.
  • 8Minns RJ, Bibb R, Banks R, et al. The use of a reconstructed three-dimensional solid mode/ from CT to aid the surgical management of a total knee arthroplasty: a case study[J]. Med Eng Phys, 2003, 25(6): 523-526.
  • 9Silva DN, Gerhardt de Oliveira M, Meurer E, et al. Dimensional error in selective laser sintering and 3D-printing of models for eranionmx- illary anatomy reconstruction[J]. J Craniomaxillofac Surg, 2008, 36 (8): 443-449. DOI: 10. 1016/j. ictus. 2008.04. 003.
  • 10Lombardi AV Jr, Berend KR, Adams JB, et al. Patient-specific ap- pnmch in total knee arthroplasty[J] . Orthopedics, 2008, 31(9): 927.

共引文献104

同被引文献7

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部