摘要
介绍海南核电有限公司1号机组2号主汽阀阀碟断裂事故及处理过程,分析主汽阀缺陷产生的原因,并就主汽阀维护管理工作提出建议。
The fracture accident and treatment process of the valve disc of No.2 stop valve disc of unit 1 in Hainan Nuclear Power Company Limited was introduced in this paper.The causes of stop valve defects were also carefully analyzed,and some suggestions on the maintenance and management of stop valves were put forward.
作者
冯思超
王启超
赵银
FENG Sichao;WANG Qichao;ZHAO Yin(Hainan Nuclear Power Co.Ltd.,Haikou 570105,China)
出处
《电工技术》
2018年第2期62-64,共3页
Electric Engineering
关键词
主汽阀
阀碟
断裂
油动机缺陷
stop valve
valve disc
fracture
oil engine defects