本文介绍俄供БВД-3400-3000У3型核电无刷励磁机旋转整流回路的一起故障情况,并进行了原因分析与处理,在此基础上制定了预防性检查措施,为同类设备的运行维护提供参考。
This paper introduces a fault condition of the rotating rectification circuit of a RussianБВД-3400-3000У3 brushless nuclear power generating exciter.The causes are analyzed and the fault is treated.On this basis,the preventive measures have been developed and the reference for the operation and maintenance of similar equipment is proposed.
作者
王波
莫晶晶
张轩
WANG Bo;MO Jingjing;ZHANG Xuan(Jiangsu Nuclear Power Co.Ltd.,Lianyungang 222000,China)
出处
《电工技术》
2018年第2期80-82,共3页
Electric Engineering
关键词
无刷励磁
旋转整流回路
直流引线
brushless excitation
rotating rectifier circuit
DC lead