期刊文献+

Fenton氧化处理电镀废水的研究 被引量:1

Study on Treatment of Wastewater by Fenton oxidation
下载PDF
导出
摘要 对Fenton氧化处理电镀废水进行了研究,探讨了Fenton反应中的H_2O_2投加量、Fe^(2+)与H_2O_2的物质的量比、pH值以及反应时间对COD去除效果,得到的最佳Fenton工艺参数为:H_2O_2投加量为0.06mol/L、[Fe^(2+)]/[H_2O_2]为1∶3、pH值为3、反应时间40min、反应温度25℃。在此条件下,废水COD从原来2750mg/L降为441mg/L,COD去除率可达到83.95%。 The treatment of electroplating wastewater by Fenton oxidation method was studied.The effect of H2O2 dosage,The molar ration of Fe 2+and H2O2,pH and reaction time on the removal efficiency of COD were investigated.the best Fenton process parameters were as follows:dosage of H2O2 is 0.06mol/L,the mole ratio of Fe 2+and H2O2 is 1/3,initial pH of reaction is 3,reaction time and temperature are 40min and 25℃respectively.Under this condition,the COD in the water can be reduced from 2750mg/L to 441 mg/L,COD removal rate reached 83.95%.
作者 张存芳 王鹏程 吕斯濠 范洪波 兰善红 赵新 Zhang Cunfang;Wang Pengcheng;Lyu Sihao;Fan Hongbo;Lan Shanhong;Zhao Xin(School of Chemical Engineering and Energy Technology,Dongguan University of Technology,Dongguan 523808,China;China National Electric Apparatus Research Institute Co.,Ltd.,Guangzhou 510300,China;Guangdong Hua Yue Environmental Protection&Technology Co.,Ltd.,Foshan 528308,China)
出处 《山东化工》 CAS 2018年第6期165-167,共3页 Shandong Chemical Industry
基金 东莞市产学研合作资助项目(2015509117202) 佛山市科技创新项目(2016IT100133) 广东省自然科学基金资助项目(2016A030313136) 东莞市社会科技发展项目(201406101011)
关键词 FENTON氧化 废水 去除率 Fenton oxidation wastewater removal rate