通过对水量、水质的可靠性分析,以及对污染因子处理工艺和生产线路等方面的讨论,研究以城市中水替代河水水源利用到锅炉补给水处理系统的可行性.同时对现有系统进行研究及两种水质作全年对比分析,论证中水替代河水的可行性,最终得出城市中水可以替代河水作为补给水水源的结论.
Through the analysis of water quantity,water quality reliability,as well as pollution factors treatment technology and production lines,the feasibility of using reclaimed water in city instead of the water sources from river to provide the boiler Make-up water treatment system is studied.At the same time,the present systems is researched and the two kinds of water quality are compared in whole year to demonstrate the feasibility of replacing the river water by reclaimed water,and finally it draws a conclusion that reclaimed water can replace the river water as the water source of the boiler Make-up water.
作者
邓悦
王立刚
房辉
张佳宁
余卫东
沈卫军
杨修军
DENG Yue;WANG Ligang;FANG Hui;ZHANG Jianing;YU Weidong;SHEN Weijun;YANG Xiujun(Zhejiang Zheneng Changxing Electric Power Generation Co.Ltd,Huzhou 313000,China)
出处
《湖州师范学院学报》
2018年第2期57-62,共6页
Journal of Huzhou University
关键词
节能减排
城市中水
污染因子
活性炭吸附
energy conservation and emission reduction
reclaimed water
pollution factors