摘要
华夏电力公司对四台机组进行汽轮机高低压缸通流改造,改造后,每台汽轮机偏心通道都出现过运行中旁路、偏心测量数值无显示现象。对查找原因的详细过程和最终解决方案进行归纳整理,方便人们处理同类型汽轮机改造后的偏心测量问题,推广应用价值较高。
Huaxia electric power company has carried out the transformation of turbine’s high and low pressure cylinder through four units.After retrofitting,every steam rtbuine eccentric channel has appeared in operation bypass and eccentric measurement value.The detailed process and final solution fo r finding the cause are summarized.It is convenient for people to deal with the eccentric measurement of the same type of stea m turbine after retrofit.The scheme has high popularization an d application value.
作者
邱巍玲
QIU Weiling(Xiamen Huaxia International Power Development Co.,Ltd.,Xiamen 361026)
出处
《现代制造技术与装备》
2018年第3期164-165,共2页
Modern Manufacturing Technology and Equipment
关键词
通流改造
汽轮机偏心
11mm探头
flow through transformation
steam turbine eccentricity
11mm probe