期刊文献+

Simulation study on characteristics of information extraction in multiple-image radiography

Simulation study on characteristics of information extraction in multiple-image radiography
下载PDF
导出
摘要 Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were added to the simulation, and the results show that Poisson noise deteriorates the extraction results, with the degree of refraction > USAXS > absorption. The effects of Poisson noise are negligible when the detector's photon counts are about 1000 ph/pixel. A wider sampling range allows more accurate extraction results, but a narrower sampling range has a better signal-to-noise ratio for high Poisson noise levels, e.g., PN(10). The sampling interval can be suitably increased with a minor impact on the extraction results for low Poisson noise levels(PN(10000)). The extraction results are incomplete because a portion of the samplerocking curve is beyond the sampling range. This induces artifacts in the images, especially for strong refraction and USAXS signals. The artifacts are not obvious when the refraction angle and standard deviation of the USAXS are smaller than the sampling range by an order of magnitude.In general, the absorption barely affects the extraction results. However, additional Poisson noise will be generated when the sample is made of high-Z elements or has a large size due to the strong absorption. Here, the extraction results will deteriorate, and additional exposure time is required. This simulation provides important details on practical applications of MIR, with improvements in information extraction. Simulation experiments were performed to investigate the characteristics of information extraction in multiple-image radiography(MIR) based on geometrical optics approximation. Different Poisson noise levels were added to the simulation, and the results show that Poisson noise deteriorates the extraction results, with the degree of refraction > USAXS > absorption. The effects of Poisson noise are negligible when the detector's photon counts are about 1000 ph/pixel. A wider sampling range allows more accurate extraction results, but a narrower sampling range has a better signal-to-noise ratio for high Poisson noise levels, e.g., PN(10). The sampling interval can be suitably increased with a minor impact on the extraction results for low Poisson noise levels(PN(10000)). The extraction results are incomplete because a portion of the samplerocking curve is beyond the sampling range. This induces artifacts in the images, especially for strong refraction and USAXS signals. The artifacts are not obvious when the refraction angle and standard deviation of the USAXS are smaller than the sampling range by an order of magnitude.In general, the absorption barely affects the extraction results. However, additional Poisson noise will be generated when the sample is made of high-Z elements or has a large size due to the strong absorption. Here, the extraction results will deteriorate, and additional exposure time is required. This simulation provides important details on practical applications of MIR, with improvements in information extraction.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第5期87-97,共11页 核技术(英文)
基金 supported by the Fundamental Research Funds for the Central Universities of Ministry of Education of China(Nos.lzujbky-2016-208 and lzujbky-2016-32) the Lanzhou University Construction Project for Innovation and Cooperative Education Base
关键词 X-ray imaging Phase CONTRAST ROCKING CURVE Multiple-image RADIOGRAPHY X-ray imaging Phase contrast Rocking curve Multiple-image radiography
  • 相关文献

参考文献3

二级参考文献23

  • 1朱昌盛,王智平,荆涛,柳百成.对流影响枝晶生长的相场法模拟研究进展[J].材料导报,2004,18(12):26-28. 被引量:8
  • 2朱佩平,王寯越,袁清习,田玉莲,黄万霞,黎刚,胡天斗,姜晓明,吴自玉.两块晶体衍射增强成像方法研究[J].物理学报,2005,54(1):58-63. 被引量:23
  • 3黄万霞,袁清习,田玉莲,朱佩平,姜晓明,王寯越.同步辐射硬x射线衍射增强成像新进展[J].物理学报,2005,54(2):677-681. 被引量:40
  • 4朱佩平,袁清习,黄万霞,王寯越,舒航,吴自玉,冼鼎昌.衍射增强成像原理[J].物理学报,2006,55(3):1089-1098. 被引量:15
  • 5R. N. Grugel.Secondary and tertiary dendrite arm spacing relationships in directionally solidified Al-Si alloys[J]. Journal of Materials Science . 1993 (3)
  • 6P. W. Peterson,T. Z. Kattamis,A. F. Giamei.Coarsening kinetics during solidification of Ni-Al-Ta dendritic monocrystals[J]. Metallurgical Transactions A . 1980 (6)
  • 7K. P. Young,D. H. Kerkwood.The dendrite arm spacings of aluminum-copper alloys solidified under steady-state conditions[J]. Metallurgical Transactions A . 1975 (1)
  • 8Daye D M.Solidification of Metals and Alloys. . 1983
  • 9Jie W Q,Zhou Y H.A model study on the transition from columnar crystal zone to equiaxed. J Northwest Polytechnical Univ . 1988
  • 10Thi H N,Jamgotchian H,Gastaldi J,et al.Preliminary in situ and real-time study of directional solidification of metallic alloys by X-ray imaging techniques. J Phys D:App Phys . 2003

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部