期刊文献+

玻璃烧结电连接器插针断裂成因判定 被引量:2

Cause Determination of Pin Breakage from Glass Sintered Electrical Connector
原文传递
导出
摘要 以某玻璃烧结电连接器为例,对其插针断裂故障成因进行判定。通过宏观观察、孔位坐标、壳体尺寸和断口等方面的分析,确定故障是由于低应力作用下的高周疲劳引起的多源疲劳。分析产品的封接、插接的操作过程,结合振动试验判定故障成因,表明壳体尺寸不合格加剧了孔位坐标偏差,两者共同造成了裂纹处的初始应力。初始应力和振动共同作用造成了插针断裂故障。 By taking a glass sintered electrical connector as an example,the cause of the pin breakage is determined.Through macroscopical observation,coordinate analysis of hole position,shell size analysis and fracture analysis,it is determined that the failure is originated from multi-source fatigue of highcycle fatigue under low stress.The sealing and the plug process are analyzed combining the vibration test,showing that the size of the shell is not qualified,which aggravates the hole coordinate deviation,and these both cause the initial stress at the breakage.The joint factors of initial stress and vibration cause the fault of the pin breakage.
作者 杨贺 张文秀 高玉勇 YANG He;ZHANG Wen-xiu;GAO Yu-yong(Shenyang Xinghua Aero-electric Appliance Co.,Ltd.,Shenyang 110144,China)
出处 《工业技术创新》 2018年第2期70-72,共3页 Industrial Technology Innovation
关键词 玻璃烧结 电连接器 断裂 插针 Glass Sintered Electrical Connector Breakage Pin
  • 相关文献

参考文献9

二级参考文献56

共引文献56

同被引文献28

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部