摘要 某地面发射系统防护塔顶部的水平防护门必须在火箭起飞后极短地时间内在保证不碰撞箭体的前提下完全关闭,以达到对其内部液氢加泄连接器、管路、电子设备等进行防护的目的,避免燃气流直接冲击带来巨大损失及危险。经计算分析,最终采用了水平及竖直方向各2种气缸的冗余方案。完成了总计超过1300次试验验证,压力2.4MPa,防护门关闭时间小于1.2s。 To protect the hydrogen connectors,pipes,etc from directly impacting of gas flow which probably caused huge losses and risk,the horizontal protective door of liquid hydrogen tower must completely be closed within a very short time after rocket takeoff,under condition of non impact to rocket.Through the simulation analysis,the redundancy scheme with 2 cylinders both in horizontal and vertical direction is applied.Through more than 1300 tests,using the pressure of 2.4MPa,the closing time of the protective door is less than 1.2s.
作者 胡亚涛 杨俊恒 Hu Ya-tao;Yang Jun-heng(Beijing Space Launch Technology Research Institute,Beijing,100076)
出处 《导弹与航天运载技术》 CSCD 北大核心 2018年第2期87-89,120,共4页 Missiles and Space Vehicles
关键词 防护塔 气缸 仿真计算 试验 Protective tower Cylinder Simulation Test
  • 相关文献

参考文献4

二级参考文献6

  • 1华自强.工程热力学[M].北京:人民教育出版社,1982..
  • 2夏廷栋.液压传动的密封与密封原理[M].北京:中国农业机械出版社,1982..
  • 3南京航空学院,传热学,1982年
  • 4范治新,工程传热原理,1982年
  • 5华自强,工程热力学,1982年
  • 6夏廷栋,液压传动的密封与密封原理,1982年