期刊文献+

重整加热炉合同能源管理项目实施效果及分析

Application Analysis of Reformer Furnace EMC Project
下载PDF
导出
摘要 中国石化武汉分公司重整装置四合一加热炉F-203采用合同能源管理模式进行了强化传热改造,改造后的加热炉F-203节能16.48%,节能效果明显,在相同工艺条件下每开满一年可节约燃料费用近200万元,经济效益显著。目前已完成合同能源管理模式的整个合同周期,为今后执行相关模式操作提供了有益的经验。 Enhanced heat transfer modification is carried out by Energy Management Contract(EMC)Mode on the"four-in-one"furnace F-203 of Reforming Unit in Sinopec Wuhan Company.After modification,energy-saving of the furnace F-203 is remarkable,and energy-saving rate reaches 16.48%.Economical profit is also significant.Under the same conditions,nearly 2 million yuan can be saved in fuel costs.Now the whole contract period of the Energy Management Contract Mode has been completed,which provides good experiences for future operations.
作者 肖翔 邓云清 Xiao Xiang;Deng Yunqing(Sinopec Wuhan Company,Wuhan Hubei 430082,China)
出处 《石油石化绿色低碳》 2018年第2期39-42,共4页 Green Petroleum & Petrochemicals
关键词 重整加热炉 合同能源管理 强化传热改造 reforming furnace contract energy management enhanced heat transfer modification
  • 相关文献

参考文献1

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部