摘要
样品经灼烧除去硫、碳、砷、汞等,再经王水溶解。取部分溶液在10%盐酸溶液中,用甲基异丁基酮(MIBK)萃取,火焰原子吸收法测定样品中的金。该方法检出限为0.10μg/g,相对标准偏差为2.13%-3.98%。经国家一级标准物质验证,该方法分析结果与标准值相符,且操作步骤简便、快速和选择性高,可用于大批量样品的检测。
Samples were burned to remove sulfur,carbon,arsenic,mercury,and then dissolved in aqua regia.Take part of the solution in 10%hydrochloric acid solution,with methyl isobutyl ketone(MIBK)extraction,flame atomic absorption spectrometry of gold in the sample.The detection limit of the method was 0.10μg/g,the relative standard deviation was 2.13%~3.98%.The national standard material verification,the method analysis results consistent with the standard value,and the operation steps are simple,fast and high selectivity,can be used for testing large quantities of samples.
作者
房宏伟
Fang Hongwei(Sinochem Geology and Mineral Resources Bureau of Hebei Geological Prospecting Institute Shijiazhuang,Shijiazhuang 050031,China)
出处
《云南化工》
CAS
2018年第2期64-66,共3页