摘要
在组合梁参数化有限元模型的基础上,改变连接件间距,进行了6根不同剪力连接度组合梁的非线性分析.结果表明:当剪力连接度大于0.6时,适当地改变其大小对组合梁非线性性能影响较小,实际工程中使用部分连接组合梁是切实可行的.
Based on the parametric finite element model of composite beams,the nonlinear analysis of 6 composite beams with different shear connection degrees is carried out by changing the space between the connectors.The analysis shows that when the shear connection degree is greater than 0.6,it has little effect on the nonlinear performance of the composite beam to change its size appropriately,and it is feasible to use the partially connected composite beam in the actual engineering.
作者
火东存
段运
李小雪
HUO Dong-cun;DUAN Yun;LI Xiao-xue(Shaanxi Railway Institute,Weinan Shaanxi 714000,China;Design Institute of China Railway Eleven Bureau,Wuhan 430061,China)
出处
《兰州工业学院学报》
2018年第2期32-34,共3页
Journal of Lanzhou Institute of Technology
基金
陕西铁路工程职业技术学院2016年第二批科研基金项目(KY2016-37)
关键词
组合梁
剪力连接度
非线性
composite beam
degree of shear connection
nonlinear