摘要
针对主变压器A/B/C三相和厂用变压器变A/B两相以及备用主变和备用厂变的火灾风险,核电站为每一个变压器设计了一套自动高速水喷雾灭火系统进行保护,能够及时扑灭变压器的火灾,最大程度地减少设备损失。论文对核电站消防喷淋系统组成和原理进行了介绍,以帮助维修人员进一步了解该系统。
For the fire risk of all transformer,such as A/B/C three phases main transformer,A/B two phases station transformer,standby main transformer and standby station transformer,the nuclear power plant designed a automatic high speed water spray system for each transformer,the transformer can be extinguished in time to minimize equipment loss.The composition and principle of fire sprinkler system in nuclear power plant are introduced in this paper,to help maintenance personnel to learn more about the system.
作者
雍政
YONG Zheng(China General Nuclear Power Operation Co.Ltd.,Yangjiang 529500,China)
出处
《中小企业管理与科技》
2018年第12期159-160,共2页
Management & Technology of SME
关键词
火灾
消防喷淋
组成
原理
fire
fire sprinkler
composition
principle