根据三菱M701F4控制系统(TCS)没有分散度监控,不能对燃烧工况进行全方面监控的情况,研究设计出可以对燃烧筒及透平燃烧工况、高低温区,进行全方位监控的分散度监控系统。
According to the Mitsubishi M701F4 control system(TCS),there is no divergence monitoring,it can't monitor the combustion conditions in all aspects.The research scheme is designed to monitor the over-all divergence of combustion cylinder and turbine combustion conditions,high and low temperature region.