摘要
利用FLUENT软件对某1 000 MW塔式锅炉的燃烧过程进行了数值模拟。结果表明:在额定工况下,温度在炉膛内呈左右对称分布,高温区出现在燃烧器区域的中上部;锅炉冷灰斗区域的温度最低;沿射流方向靠近下游水冷壁处的温度高、氧浓度低,在运行中要注意下游水冷壁区域的结渣情况。
In order to study the combustion of 1 000 MW tower boiler in operation,the combustion process of a 1 000 MW tower boiler is simulated by FLUENT software.The results show that under the BMCR working condition,the temperature is symmetrical distribution in the furnace and the high temperature region appears in the middle and upper part of the burner area.The temperature at the area of the furnace hopper is the lowest.The position close to downstream water-wall along the jet direction is easy to slag.
作者
管明健
李彦
马晟恺
GUAN Mingjian;LI Yan;MA Shengkai(Shanghai University of Electric Power,Shanghai 200090,China;Huaneng(Shanghai)Power Maintenance Co.,Ltd,Shanghai 200942,China)
出处
《上海电力学院学报》
CAS
2018年第2期115-118,共4页
Journal of Shanghai University of Electric Power
基金
上海市科学技术委员会项目(18020501000)
关键词
锅炉
四角切圆燃烧
偏置风
结渣
数值模拟
boiler
tangential combustion
off-center air
lagging
numerical simulation