摘要 建立了一种实时直接分析-质谱法(DART-MS)用于饮料(水、碳酸饮料、啤酒)和尿液中γ-羟基丁酸(GHB)快速检测。样品经甲醇-水(1∶1,V/V)溶液稀释后,在负离子模式下,以选择离子扫描(SIR)模式进行直接定量分析。离子化气体温度为350℃,进样速率为0.5 mm/s。针对水样、碳酸饮料、啤酒、尿液样品,本方法的检出限(S/N=3)为1~2μg/m L,定量限(S/N=10)为3~5μg/m L。标准曲线线性相关系数为0.9899~0.9980,加标回收率为80.8%~115.2%,相对标准偏差为1.9%~12.8%。本方法具有样品前处理简单、分析速度快、成本低等优点,有望在大批量饮料和尿液样品的快速筛查分析中发挥作用。 A method for rapid determination ofγ-hydroxybutyric acid(GHB)in beverages(water,sodas,beer)and urine was established by direct analysis real-time mass spectrometry(DART-MS).Samples were analyzed directly after dilution with mixture of methanol and water(1∶1,V/V).Instrument parameter settings were optimized to obtain the sensitive and accurate determination of GHB.At the sample introduction speed of 0.5 mm/s,high intensity of[M-H]0x0E?Symbolm@@0x0F ions for GHB were observed in the negative ion and selection ion monitoring mode by utilization of high purity helium gas at 350℃.For different samples of water,sodas,beer and urine,the limits of detection(LODs)(S/N=3)were in the range of 1-2μg/mL,while the limits of quantification(LOQs)(S/N=10)were in the range of 3-5μg/mL.The linear correlation coefficients of the standard curves with different sample matrixes were between 0.9899 and 0.9980.The recoveries were in the range of 80.8%-115.2%with the relative standard deviations of 1.9%-12.8%.With its rapid analysis and simple pretreatment steps,the method is expected to have a strong advantage in the rapid screening analysis of large quantities of beverage and urine.
作者 刘佳蓉 黄忠平 刘会君 王丽丽 刘春胜 任一平 史鸿鑫 LIU Jia-Rong;HUANG Zhong-Ping;LIU Hui-Jun;WANG Li-Li;LIU Chun-Sheng;REN Yi-Ping;SHI Hong-Xin(College of Chemical Engineering,Zhejiang University of Technology,Hangzhou 310014,China;ASPEC Technologies Limited,Beijing 100101,China;National Center for Food Safety Risk Assessment Application Technology Cooperation Center,Yangtze Delta Region Institute of Tsinghua University,Jiaxing 314006,China)
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 2018年第5期698-703,共6页 Chinese Journal of Analytical Chemistry
基金 国家自然科学基金项目(No.51503182) 浙江省分析测试基金(No.2017C37064) 浙江省家具检测技术研究重点实验室资助项目(No.2016J01)资助~~
关键词 实时直接分析-质谱法 Γ-羟基丁酸 快速筛查 Direct analysis in real-time mass spectrometry γ-Hydroxybutyric acid Rapid screening
  • 相关文献

参考文献1

二级参考文献15

  • 1刘晓茜,沈敏,刘伟,沈保华,向平.尿液、血液中γ-羟丁酸的气质联用法分析[J].中国法医学杂志,2005,20(1):17-21. 被引量:8
  • 2Elliotta S,Loweb P,Amanda Symonds Forensic Science International,2004,139:183-190
  • 3Drasbek K R,Christensen J,Jensen K.Acta Neurologica Scandinavica,2006,114:145-156
  • 4Elian A A.Forensic Science International,2000,109:183-187
  • 5Elian A A.Forensic Science International,2001,122:43-47
  • 6Elliott S P.Forensic Science International,.2003,133:9-16
  • 7Richard P,Lolita T,Robert K,Anthony B.Journal of Analytical Toxicology,2006,30:375-379
  • 8Beránkova K,Mutnanska K,Balíkova M.Forensic Science International,2006,161:158-162
  • 9Hackett J,Elian A A.Forensic Science International,2006,157:156-162
  • 10Baptista M J,Monsanto P V.Forensic Science International,2002,128:66-78