期刊文献+

3D打印氧化锆全瓷冠的密合性研究 被引量:5

Evaluation of the fitness of zirconia crowns fabricated with 3D printing
下载PDF
导出
摘要 目的:评估3D打印技术与CAD/CAM切削技术制作的氧化锆全瓷单冠的密合性。方法:分别采用3D打印(实验组)和CAD/CAM切削(对照组)各制作10个氧化锆全瓷单冠,通过"硅橡胶法"和三维偏差分析软件Geomagic Qualify测量其冠边缘及内部的密合性,并对结果进行统计分析。结果:全瓷冠的边缘及内部密合性(μm)3D打印组分别为89±19、87±16,CAD/CAM切削组分别为94±31、107±33(P>0.05)。结论:3D打印技术制作的氧化锆全瓷单冠的密合性能满足临床要求。 AIM:To evaluate the fitness of zirconia single crowns fabricated with 3D printing.METHODS:Zirconia single crowns were processed by a 3D printing system(test group,n=10)and by a CAD/CAM milling system(control group,n=10)respectovely.Marginal fit and internal fit were examined using a light-body silicone and a 3D inspection software-Geomagic Qualify.The independent sample test was used to determine statistically significancy between the 2 groups by SPSS statistical package version 22.0.RESULTS:The fitness of marginal and internal of the crowns was(89±19)μm and(87±16)μm respectively of the 3D printing group,(94±31)μm and(107±33)μm respectively of the milling group(between 2 groups,P>0.05).CONCLUSION:The fitness of zirconia single crown produced by 3D printing meet the clinical requirements.
作者 王伟娜 于海 刘一帆 高勃(指导) WANG Wei-na;YU Hai;LIU Yi-fan;GAO Bo(State Key Laboratory of Military Stomatology&National Clinical Research Center for Oral Diseases& Shaanxi Key Laboratory of Stomatology,Department of Prosthodontics,School of Stomatology, The Fourth Military Medical University,Xi’an 710032,China)
出处 《牙体牙髓牙周病学杂志》 CAS 2018年第4期209-213,共5页 Chinese Journal of Conservative Dentistry
基金 国家自然科学基金(81170983)
关键词 3D打印 CAD/CAM切削 全瓷冠 密合性 3D printing CAD/CAM milling all-ceramic crown fitness
  • 相关文献

参考文献2

二级参考文献20

  • 1孙迎春,周晖.金沉积烤瓷冠密合度的评价[J].口腔颌面修复学杂志,2005,6(2):97-98. 被引量:18
  • 2韩东,伊哲.临床评价全冠修复体适合性的一种方法[J].实用医技杂志,2005,12(08A):2160-2160. 被引量:6
  • 3邬烈,骆小平.固定修复体适合性的研究方法[J].口腔颌面修复学杂志,2007,8(1):68-70. 被引量:18
  • 4于雪宁,杨晓东,宛莉娜.硅橡胶间隙印模检测金属烤瓷全冠适合性的可行性研究[J].中国医科大学学报,2007,36(5):569-571. 被引量:9
  • 5Kruth JP, Froyen L, Vaerenbergh .IV, et al. Selective laser mehing of iron-based powder[ J]. J Mater Process Tech, 2004, 149(s 1 -3) :616 -622.
  • 6Yap CY, Chua CK, Dong ZL, et al. Review of selective la- ser melting: Materials and applications [ J ]. Applied Physics Reviews, 2015, 2 ( 4 ) : 2071 - 2074.
  • 7Foster LV. Failed conventional bridge work from general dental practice: Clinical aspects and treatment needs of 142 cases[J]. BrDent J, 1990, 168(5):199-201.
  • 8Leong D, Chai J, Lautenschlager E, et al. Marginal fit of machine-milled titanium and cast titanium single crowns [J]. Int J Prosthodont, 1994, 7(5) :440 -447.
  • 9McLean JW, yon Fraunhofer JA. The estimation of cement fihn thickness by an in vivo technique[ J]. Br Dent J, 1971, 131(3) :107 - 111.
  • 10Mou SH, Chai T, Wang JS, et al. Influence of different convergence angles and tooth preparation heights on the in- ternal adaptation of Cerec crowns [ J ]. J Prosthet Dent, 2002, 87(3) :248 -255.