期刊文献+

数字化导板在口腔种植临床应用中的精确度评价 被引量:4

The Accuracy Evaluation of Digital Guide Plate in the Clinical Application of Oral Implant
下载PDF
导出
摘要 目的评价数字化导板在口腔种植临床应用中的精确度。方法选取本院收治的牙齿缺损患者96例作为样本,将其分为导板组与对照组两组。对照组采用常规方法种植,导板组采用数字化导板行口腔种植术。结果导板组患者角度偏差(3.91±0.06)mm、深度偏差(0.24±0.02)mm、顶部偏差(0.96±0.03)mm、根尖偏差(1.32±0.11)mm、探针深度(5.10±0.27)mm、改良出血指数(0.85±0.03)、并发症发生率2.08%、生活质量(97.49±1.79)分,优势显著(P<0.05)。结论将数字化导板应用到口腔种植术中,可有效提高种植体植入的精确度,改善预后,提高治疗的安全性。 Objective To evaluate the accuracy of clinical application of digital guide plate in oral implant.Methods 96 patients with dental defects were selected as samples.They were divided into two groups:the guide group and the control group.The control group was implanted with conventional method and the guide group was treated with digital guide plate.Results The angle deviation of the patients in the guide group was(3.91±0.06)mm.The depth deviation was(0.24±0.02)mm,the top deviation was(0.96±0.03)mm,and the root tip deviation was(1.32±0.11)mm.The probe depth was(5.10±0.27)mm,and the improved bleeding index was(0.85±0.03),the incidence of complications was 2.08%and the quality of life was(97.49±1.79),with a significant advantages(P<0.05).Conclusion The application of digital guide plate in oral implant can effectively improve the accuracy of implant implantation,improve the prognosis and improve the safety of treatment.
作者 陈赫男 CHEN Henan(Department of Stomatology,Heilongjiang Forestry General Hospital,Harbin Heilongjiang 150040,China)
出处 《中国卫生标准管理》 2018年第8期40-41,共2页 China Health Standard Management
关键词 数字化导板 口腔种植 精确度 digital guide plate dental implant accuracy
  • 相关文献

参考文献9

二级参考文献55

  • 1Hultin M,Svensson KG,Trulsson M,Clinical advantages of computer-guided implant placement: a systematic review[J].Clin Oral Implants Res,2012,23(Suppl 6):124-135.
  • 2Fortin T,Isidori M,Bouchet H. Placement of posterior maxillary implants in partially edentulous patients with severe bone deficiency using CAD/CAM guidance to avoid sinus grafting: a clinical report of procedure[J]. Int J Oral Maxillofac Implants, 2009, 24(1):96-102.
  • 3Brodala N. Flapless surgery and its effect on dental implant outcomes[J]. Int J Oral Maxillofac Implants, 2009,24 (Suppl): 118-125.
  • 4Sanna AM, Molly L, van Steenberghe D. Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients[J]. J Prosthet Dent, 2007,97(6): 331-339.
  • 5Mericske-Stern RD,Taylor TD,Belser U. Management of the edentulous patient[J]. Clin Oral Implants Res,2000,11(Suppl 1):108-125.
  • 6Van Assche N, Vercruyssen M,Coucke W,et al. Accuracy of computer-aided implant placement[J]. Clin Oral Implants Res, 2012, 23 (Suppl 6):112-123.
  • 7Almog DM,Torrado E,Meitner SW. Fabrication of imaging and surgical guides for dental implants[J].The Journal of Prosthetic Dentistry,2001,(5):504-508.
  • 8D'Souza KM,Aras MA. Types of implant surgical guides in dentistry:A review[J].{H}Journal of Oral Implantology,2012,(5):643-652.
  • 9Block MS,Chandler C. Computed tomography-Guided surgery:Complications associated with scanning,processing,surgery,and prosthetics[J].{H}Journal of Oral and Maxillofacial Surgery,2009,(11):13-22.
  • 10Ramasamy M,Raja R,Narendrakumar R. Implant surgical guides:From the past to the present[J].Journal of Pharmacy And Bioallied Sciences,2013,(5):98.