期刊文献+

一种快速准确测量照明空间统一眩光指数的方法 被引量:3

A Fast and Accurate Method for Measuring Lighting Space UGR
下载PDF
导出
摘要 现有的眩光测量方法不能明确找出照明空间最大统一眩光值(UGR)的所在点,所测得的UGR值也不一定是该空间的最大值,而且测量工作较为繁杂。为了快速准确地测得照明空间的UGR值,本文提出先用Dialux evo软件仿真计算,依据仿真计算结果设置UGR测点,再来测量UGR的方法,并在暗室中对该方法进行了实验验证。从实验结果来看,该方法不仅可以减少需设置的测点数、减少繁杂的测量工作,而且能求得被测空间最大UGR值。 Existing glare measurement methods can not clearly identify the point where the maximum UGR of illumination space is located,and the measured UGR value is not necessarily the maximum value of the space,and the measurement work is complicated.In order to quickly and accurately measure the UGR value of illumination space,this paper proposes a method to set UGR measurement point first and then measure UGR by using Dialux evo software simulation,and then validates the method in darkroom.The experimental results show that this method can not only reduce the number of measurement points to be set,reduce the cumbersome measurement work,but also obtain the maximum UGR value of the measured space.
作者 王银飞 张晓晖 张爽 张雨晨 WANG Yinfei;ZHANG Xiaohui;ZHANG Shuang;ZHANG Yuchen(College of Weaponry,Naval University of Engineering,Wuhan 430000,China)
出处 《照明工程学报》 2018年第2期1-5,11,共6页 China Illuminating Engineering Journal
关键词 眩光 测量 DIALUX evo仿真 统一眩光指数 照明 glare measurement Dialux evo software simulation UGR lighting
  • 相关文献

参考文献5

二级参考文献29

  • 1Guth. A method for the evaluation of discomfort glare.IES, 57, 351 - 364. 1963
  • 2Fisher D. European glare hmiting method. Lighting Research & Technology, 4, 97 - 100. 1972
  • 3Manabe H. The assessment of discomfort glare in practical lighting installation. Oteman Economics Studies, No. 9, Osaka, Japan; Oteman Gakuin University. 1976
  • 4CIBSE Technical Memorandum 10. The Calculation of Glare Indices, London CIBSE. 1985
  • 5Sorensen K. Practical aspects of discomfort glare evaluation: interior lighting. Proceedings of the First International Symposium on Glare, New York: Lighting Research Institute. 1991
  • 6CIE 55 - 1983. Discomfort Glare in the Interior Working Environment.
  • 7CIE 117 - 1995. Discomfort Glare in Interior Lighting.
  • 8CIE 146- 2002. CIE Collection on Glare
  • 9Einhom. Minutes of TC 3 - 01 meetings. 1994 -1995.
  • 10Boyce P. R. Human Factors in Lighting. 2^nd ed.,2003, Taylor & Francis, London