期刊文献+

电容式微超声波换能器的设计与电容值测试 被引量:3

Design of capacitance micro ultrasonic transducer and test of capacitance value
下载PDF
导出
摘要 该文通过对电容式微超声波换能器电容值测试分析了传感器的电容性能。该文设计的电容式微超声波换能器是由电容阵列组成的,主要是利用电容的改变来实现能量的转换。它是基于硅硅键合技术的微机电系统的电容式超声传感器,由其制作的传感器误差小、工艺流程简单且能进行量产。利用E4990A阻抗分析仪测试传感器电容值在工作电压下随频率的变化,得出频率为400 k Hz时电容值为617.67 p F。并且利用该仪器对传感器进行C-V测试分析而得出其电容的实际值与理论值的误差仅为1.6%。所得结果为对传感器进行理论计算提供了重要支撑,并且为后续转换电路的设计提供了数据支撑。 In this letter,we analyzed the capacitance performance of the sensor through measuring the capacitance of a capacitance-micro-ultrasonic-transducer.The capacitance-micro-ultrasonic-transducer we designed is composed of capacitance array,which mainly uses the change of capacitance to realize the conversion of energy.It is a capacitive ultrasonic sensor based on Si-Si bonding technology for MEMS.Further,the sensor has a small error and can be mass-produced due to it’s simple process.The E4990A impedance analyzer is used to test the change of the capacitance value of the sensor with the frequency under the working voltage,and the capacitance value is 617.67 pF when the frequency is 400 kHz.In addition,we obtain that the error of sensor’s capacitance between actual and theoretical value is only 1.6%by test and analyze the sensor’s C-V characteristics with our instrument.The results provide an important support for the theoretical calculation of the sensor,and provide data support for the design of the subsequent conversion circuit.
作者 贾利成 何常德 杜以恒 薛晨阳 张文栋 JIA Licheng;HE Changde;DU Yiheng;XUE Chenyang;ZHANG Wendong(Key Laboratory of Instrumentation Science&Dynamic Measurement,Ministry of Education,North University of China,Taiyuan 030051,China)
出处 《应用声学》 CSCD 北大核心 2018年第4期504-508,共5页 Journal of Applied Acoustics
基金 国家重点研发项目(2016YFC0101900) 国家杰出青年科学基金项目(61525107)
关键词 微机电系统 ANSYS 电容式微超声波换能器 E4990A阻抗分析仪 工艺流程 Micro-electro-mechanical system ANSYS Capacitance micro ultrasonic transducer E4990A impedance analyzer Process flow
  • 相关文献

参考文献2

二级参考文献20

  • 1杜功焕.声学基础[M].北京:北京科学技术出版社,1986..
  • 2张慧,宋光德,栗大超,官志坚,靳世久.一种微加工超声传感器的设计[J].天津大学学报,2008,41(1):17-20. 被引量:5
  • 3ZHANG W, ZHANG H, DU F, et al. Pull-In analysis of the flat circular CMUT cell featuring sealed cavity [ J ]. Mathematical Problems in Engineering, 2015, 2015 (6) : 1-9.
  • 4ORALKAN O, ERGUN A S, JOHNSON J A, et al. Capacitive micromachined ultrasonic transducers: next- generation arrays for acoustic imaging [ J ]. IEEETransactions on Uhrasonics Ferroelectrics & Frequency Control, 2002, 49( 11 ) :1596-1610.
  • 5BAO M H. Analysis and design principles of MEMS devices [ M ]. The Netherlands : Elsevier, 2005.
  • 6APTE N, PARK K K, KHURI-YAKUB B T. Experimental evaluation of CMUTs with vented cavities under varying pressure [ J ]. IEEE International Ultrasonics Symposium, 2013,47 ( 1 ) : 1724-1727.
  • 7APTE N, PARK K K, NIKOOZADEH A, et al. Bandwidth and sensitivity optimization in CMUTs for airborne applications [ C ]. IEEE Ultrasonics Symposium, 2014 : 166-169.
  • 8CHA B S, LEE S M, KANASHIMA T, et al. Influences of perforation ratio in characteristics of capacitive micromachined ultrasonic transducers in air [ J ]. Sensors & Actuators A Physical, 2011, 171(2) :191-198.
  • 9ZHANG Q, CICEK P V, ALLIDINA K, et al. Surface- micromachined CMUT using low-temperature deposited silicon carbide membranes for above-IC integration [ J ]. Journal of Microelectromechanical Systems, 2014, 23(23) :482-493.
  • 10王器壶.微系统设计与制造[M].北京:清华大学出版社,2008.