摘要
通过对比固原地电场2011、2015年固体不极化电极的埋设情况,分析更换电极后观测资料质量的变化和成因,总结出了埋设固体不极化电极时需特别注意的事项:(1)固体不极化电极的稳定剂需与大地充分接触,保证可靠的接地电阻;(2)埋设电极的极坑应尽可能的保持潮湿,以延长电极的使用寿命。
By comparing the embedment of solid non-polarizable electrodes in Guyuan Geoelectric Field in 2011 and 2015,and analyzing the changes and causes of observation data after replacing the electrodes,we concluded that special attentions should be paid when embedding a solid non-polarizable electrode.(1)The stabilizer of the solid non polarizable electrode needs to be fully contacted with the earth to ensure reliable grounding resistance;(2)The polar pits of the buried electrodes should be kept as moist as possible to prolong the service life of the electro des.
作者
李学波
贺嘉伟
LI Xue-bo;HE Jia-wei(Earthquake Administration of Ningxia Hui Autonomous Region,Nin gxia Yinchuan 750001,China)
出处
《防灾减灾学报》
2018年第2期63-67,共5页
Journal of Disaster Prevention And Reduction
关键词
地电场
固体不极化电极
电极埋设
geoelectric field
solid non-polarizable electrode
buried elec trode