期刊文献+

化学发光检测系统测定总甲状腺素的正确度研究 被引量:2

下载PDF
导出
摘要 目的通过3种化学发光检测系统与参考方法[同位素稀释液相色谱串联质谱法(ID-LC-MS/MS)]的比对,了解不同检测系统测定甲状腺素(T4)的正确度。方法分别采用参考方法及3种化学发光检测系统[cobas e601全自动电化学发光免疫分析仪及配套试剂(简称e601)、ARCHTECT i2000SR化学发光免疫分析仪及配套试剂(简称i2000SR)、IS1200全自动化学发光测定仪及配套试剂(简称IS1200)]平行测定40例新鲜人血清样本,对结果进行线性回归和偏移分析,评价3种检测系统检测T_4的正确度。结果 e601、i2000SR、IS1200与参考方法的线性回归方程分别为Y=0.958 2X+3.76、Y=0.747 7X+11.21、Y=0.992 5X+10.59,r^2分别为0.963 9、0.967 1、0.969 0,结果均为可接受。单个样本的相对偏移e601仅有1例超出限值,平均相对偏移为-0.83%;IS1200有2例超出限值,平均相对偏移为5.83%,偏移结果均为可接受;而i2000SR有27例超出限值,平均相对偏移为-15.24%,结果为不可接受。结论 e601和IS1200的正确度良好,而i2000SR虽然与参考方法的相关性较好,但出现较明显的系统偏移。
出处 《检验医学》 CAS 2018年第7期629-632,共4页 Laboratory Medicine
基金 "十三五"国家重点研发计划项目(2017YFF0205401)
  • 相关文献

参考文献6

二级参考文献41

  • 1Myers GL, Miller WG, Coresh J, et al. Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem, 2006, 52:5-18.
  • 2Stockl D, Reinauer H. Candidate reference method for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. Ⅰ. Method setup. Clin Chem,1993, 39:993-1000.
  • 3Thienpont LM, Leenheer AP, Sttickl D. Candidate reference method for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. II. Method Transfer. Clin Chem, 1993, 39 : 1001-1006.
  • 4Thienpont LM, Van Landuyt KG, Stokl D, et al. Candidate reference method for determining serum creatinine by isocratic HPLC: validation with isotope dilution gas chromatography-mass spectrometry and application for accuracy assessment of routine test kits. Clin Chem, 1995, 41:995-1003.
  • 5Siekmann L. Determination of creatinine in human serum by isotope dilution-mass pectrometry. J Clin Chem Clin Biochem,1985, 23 : 137-144.
  • 6Welch M J, Cohen A, Hertz HS, et al. Determination of serum creatinine by isotope dilution mass spectrometry as a candidate definitive method. Anal Chem, 1986,58 : 1681-1685.
  • 7Stokes P, O' Connor G. Development of a liquid chromatography- mass spectrometry method for the high-accuracy determination of creatinine in serum. J Chromatogr B Analyt Technol Biomed Life Sci, 2003, 794:125-136.
  • 8Paronl R, Arcellonl C, Fermo I, et al. Determination of creatinine in serum and urine by a rapid liquid-chromatographic method. Clin Chem, 1990, 36:830-836.
  • 9Thienpont LM, Van Landuyt KG, Stokl D, et al. Candidate reference method for determining serum ereatininc by isocratie HPLC: validation with isotope dilution gas chromatography-mass spectrometry and application for accuracy assessment of routine test kits. Clin Chem, 1995, 41:995-1003.
  • 10Zwang L, Blijenberg BG. Assessment of a selected method for creatinine with special emphasis on bilirubin interference. Eur J Clin Chem Clin Biochem,1991, 29:795-800.

共引文献39

同被引文献6

引证文献2

二级引证文献6