期刊文献+

某变电站隔离开关传动齿轮断裂的原因分析 被引量:5

Cause Analysis of Disconnector Transmission Gear Fracture in a Substation
下载PDF
导出
摘要 以某220 kV变电站隔离开关传动齿轮发生断裂为例,通过断口分析、渗透检测、光谱分析、金相分析、拉力试验及应力分析表明,齿轮的材质不合格及强度设计偏低是造成其断裂的原因,并对更换后的新齿轮进行了强度校核,校核结果显示,新齿轮的强度满足使用要求。 This paper takes the fact for example that a transmission gear in the disconnector of one transformer substation was ruptured,and goes through fracture analysis,penetration detection,spectral analysis,metallographic analysis,tensile test and stress analysis,only to find that the unqualified material and low strength design of gear are the causes for its fracture.The strength check of the new gear after replacement shows that the strength of the new gear meets the service operating requirements.
作者 叶建锋 程昕 田泽 梅云平 YE Jianfeng;CHENG Xin;TIAN Ze;MEI Yunping(Electric Power Research Institute,State Grid Hubei Electric Power Co.Ltd.,Wuhan Hubei 430077,China;Huanggang Power Supply Company,State Grid Hubei Electric Power Co.Ltd.,Huanggang Hubei 438000,China;Hubei Fangyuan Dongli Electric Power Research Co.Ltd.,Wuhan Hubei 430077,China)
出处 《湖北电力》 2018年第1期43-45,49,共4页 Hubei Electric Power
关键词 变电站 齿轮 断裂 强度校核 transformer substation gear rupture strength check
  • 相关文献

参考文献2

二级参考文献5

  • 1高强.最新有色金属金相图谱大全[M].北京:中国冶金工业出版社,2005.
  • 2GB/T 5231-2012 加工铜及铜合金牌号和化学成分[S].北京:中国国家标准化委员会,2013.
  • 3GB/T 2314-2008 电力金具通用技术条件[S].北京:中国国家标准化委员会,2009.
  • 4GB/T 1176 铸造铜及铜合金[S].北京:中国国家标准化委员会,2014.
  • 5陈家权,刘福营,苏光耀,黄海鑫,吴根深.超高压线夹端子断裂失效分析[J].华电技术,2015,37(4):28-31. 被引量:1

共引文献18

同被引文献100

引证文献5

二级引证文献24