期刊文献+

人工关节力学性能测试硬件系统

Hardware System for the Test of Artificial Joint Biomechanics
下载PDF
导出
摘要 在人工关节生物力学性能研究中,通过离体实验对内植入固定物的生物力学性能进行评价是国际上通用的方法,国内这方面的研究起步较晚,相应的测试手段缺乏,还没有形成统一的标准。该文围绕已有的力学试验机设计并搭建了完整的硬件测试系统,包括:双目视觉捕捉仪、力矩承载夹具、薄膜压力传感器等。该系统能准确地测量出各个关节相对运动角度值、外部力矩值、关节间压力值,具有较高的可靠性和稳定性,对于人工关节力学评估系统的成形和标准化具有一定的借鉴意义。 In the research of artificial joint biomechanics,it is a common method in the world to evaluate the biomechanical properties of the implanted fixtures through experiments in vitro.The domestic research started late,and the corresponding testing methods were lacking.There is still no unified standard.In this paper,a complete hardware test system was designed and built around the existing mechanical testing machine,including:binocular vision catcher,torque bearing clamp,film pressure sensor and so on.The system can accurately measure the relative motion angle value,external torque value,and inter pressure value of each joint.It has some reference significance for the forming and standardization of the artificial joints’evaluation system.
作者 侯增涛 杨朝岚 徐大众 张琴丽 尚鹏 HOU Zengtao;YANG Zhaolan;XU Dazhong;ZHANG Qinli;SHANG Peng(Shenzhen Institutes of Advanced Technology,Chinese Academy of Sciences,Shenzhen,518055)
出处 《中国医疗器械杂志》 2018年第4期256-258,共3页 Chinese Journal of Medical Instrumentation
基金 深圳市基础研究项目(JCYJ20140417113430610) 深圳市技术开发项目(CXZZ20140408153331808) 深圳市技术开发项目(CXZZ20140417113430630)
关键词 人工关节 医疗器械 力学测试 关节性能 测量系统 artificial joint medical instruments mechanical test joint performance measurement system
  • 相关文献

参考文献5

二级参考文献31

  • 1王良意,陈德玉,郭永飞,王新伟,徐建伟,王以进.前路减压不同撑开高度影响颈椎稳定性的生物力学评价[J].中国矫形外科杂志,2004,12(23):1846-1848. 被引量:7
  • 2杨双,杜扬,蒋新生,王雷,张学欣.基于超动态测试系统的压力传感器标定技术研究[J].后勤工程学院学报,2006,22(4):89-92. 被引量:13
  • 3Abdel-Aziz Y I,Karara H M.Direct linear transformation into object space coordinates in close-range photogrammetry [A].Proc Symp Close-Range Photogrammetry [C].Urbana:Univ of Illinois Urbana Champaign,1971.1-18.
  • 4Wong K W.Mathematical formulation and digital analysis in close-range photogrammetry [J].Photogrammetric Eng Remote Sensing,1975,41:1355-1373.
  • 5Macellari V.COSTEL:A computer peripheral remote sensing device for 3-dimensional monitoring of human motion [J].Med Biol Eng Comp,1983,21:311-318.
  • 6Gazzani F.Performance of a 7-parameter DLT method for the calibration of stereo-photogrammetric systems using 1-D transducers [J].J Biomed Eng,1992,14:476-482.
  • 7HAYASHI Toyohiko,KUSUMI Rika,MIYAKAWA Michio.Calibration of linear CCD cameras used in the detection of the position of the light spot [J].IEICE Trans Info & Syst,1993,E76-D(8):912-918.
  • 8An HS, Evanich C J, Nowicki BH,et al. Ideal thickness of Smith-Robinson graft for anterior cervical fusion. A cadaveric study with computed tomographic correlation [J]. Spine, 1993,18 (14) :2043-2047.
  • 9White AA, Panjabi MM. Biomechanical consideration in the surgical management of cervical spondylotic myelopathy[J]. Spine, 1988,13:856.
  • 10Tanaka M. A pathologic study of discs in the elderly [ J ]. Spine,1993,18(11) :1456 - 1462.

共引文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部