摘要 心血管疾病成为威胁人类生命健康的重大疾病,心排量是心血管功能的重要指标,监测心排量及相关血液动力学参数有重要的临床价值。该文从有创、微创、无创三个方面,总结了各种监测技术的发展历史、原理、方法及其优缺点,并对心排量监测技术的发展和应用做了展望。 Cardiovascular disease has become a serious disease that threatens the health of human beings,cardiac output is an important indicator of cardiovascular function,monitoring cardiac output and related hemodynamic parameters have significant clinical value.This article summarizes the development history,principle,method,advantages and disadvantages of various monitoring technologies from three aspects:invasive,minimally invasive and noninvasive,the development and application of cardiac output monitoring technology are prospected.
作者 孙阳 张旭 叶继伦 彭嘉鹏 吕鹏飞 SUN Yang;ZHANG Xu;YE Jilun;PENG Jiapeng;LYU Pengfei(Biomedical Engineering Department,School of Medicine,Shenzhen University,Shenzhen,518060;Guangdong Key Lab for Biomedical Measurements and Ultrasound Imaging,Shenzhen,518060;Shenzhen Key Lab for Biomedical Engineering,Shenzhen,518060)
出处 《中国医疗器械杂志》 2018年第4期268-271,共4页 Chinese Journal of Medical Instrumentation
基金 广东省科技厅重大项目支持(2016B010108012)
关键词 心血管疾病 心排量 有创 微创 无创 cardiovascular disease cardiac output invasive minimally invasive noninvasive
  • 相关文献

参考文献1

二级参考文献14

  • 1刘琮 余珍珠 刘晓红 等.应用USCOM及超声多普勒监测正常足月新生儿的左心输出量研究.中国小儿急救医学,2007,14.
  • 2Sandham JD, Hull RD, Brant RF, et al. A randomized,controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med, 2003, 348(1): 5-14.
  • 3Connors AF Jr, Speroff T, Dawson NV, et ah The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA, 1996, 276( 11 ) : 889-897.
  • 4Knirseh W, Kretschmar O, Tomaske M, et al. Cardiac output measurement in children: comparison of the Utrasound Cardiac Output Monitor with thermodilution cardiac output measurement. Intensive Care Med, 2008, 34(6): 1060-1064.
  • 5Tan HL, Pinder M, Parsons R, et al. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth, 2005, 94(3): 287-291.
  • 6van Lelyvele-Haas LE, van Zanten AR,Borm GF, et al. Clinical validation of the non-invasive cardiac output monitor USCOM-1A in critically ill patients. Eur J Anaesthesiol, 2008, 25(11 ) : 917-924.
  • 7Wong LS, Yong BH, Young KK, et al. Comparison of USCOM ultrasonic cardiac output monitor with puhnomary artery catheter thermodilution in patients undergoing liver transplantation. LiverTranspl, 2008, 14(7): 1038-1043.
  • 8Su BC, Yu HP, Yang MVV, et al. Reliability of a new ultrasonic cardiac output monitor in recipients of living donor liver transplantation. Liver Transpl, 2008, 14(7): 1029-1037.
  • 9Chand R, Mehta Y, Trehan N. Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery.J Cardiothorac Vasc Anesth, 2006, 20(3) : 315-319.
  • 10Arora D,Chand R,Mehta Y,et al. Cardiac output estimation after off-pump coronary artery bypass: a comparison of two different techniques. Ann Card Anaesth, 2007, 10(2): 132-136.