摘要
针对某电厂600MW亚临界锅炉在低负荷时出现再热蒸汽温度偏低的实际情况,根据现场检查结果,初步分析原因;然后通过运行诊断及优化调整试验,对锅炉再热蒸汽温度偏低进行治理,取得了较好的治理效果。
In this paper,according to the field inspection results,the reason of the low reheat steam temperature in a 600MW subcritical boiler of a power plant is analyzed.Then,through the Operation Diagnosis and optimization adjustment test,the boiler reheat steam temperature is low,and a good effect is obtained.
作者
葛玉清
GE Yu-qing(Ningxia Polytechnic,Yinchuan 750001,China)
出处
《江西电力职业技术学院学报》
CAS
2018年第3期8-10,共3页
Journal of Jiangxi Vocational and Technical College of Electricity
关键词
再热汽温偏低
调整试验
汽温调节
Reheat Steam Temperature on the Low Side
Adjust the Test
Steam Temperature control