考虑蒸汽介质密度和管道摩擦阻力变化的影响,提出一种长距离输送蒸汽管道的压降和温降的计算方法。计算分析得出,保温材料及厚度、管内流速和蒸汽初始参数等都是长输蒸汽管道温降和压降的主要影响因素。
The impacts caused by the changes of both steam density and pipe friction are taken into consideration,and then a calculation method about the temperature drop and pressure drop of long-distance pipeline of steam transportation is proposed.According to calculation and analysis,it is proved that the insulation material and the corresponding thickness,velocity in pipe,initial parameters of steam and so on are the main influencing factors on temperature drop and pressure drop of long-distance steam pipeline.
作者
薛永明
朱九喜
付小平
XUE Yong-ming;ZHU Jiu-xi;FU Xiao-ping
出处
《节能》
2018年第8期40-43,共4页
Energy Conservation
关键词
蒸汽管道
压降计算
温降计算
长距离输送
steam pipeline
pressure drop calculation
temperature drop calculation
long distance transportation