期刊文献+

基于滑模移频法的光伏发电并网系统孤岛检测混合算法 被引量:7

Mixed Islanding Detection Method for Grid-connected Photovoltaic System Based on Slip-mode Frequency Shift Method
下载PDF
导出
摘要 由于孤岛现象带来的诸多危害,为保证光伏并网发电系统的安全运行,有必要对电网实行孤岛检测。首先,对基于主动移相的滑模移频法与相位突变检测法的工作原理进行阐述,并分析其在检测盲区上存在的缺陷;然后以相位为出发点,将这两种方法有机结合,提出一种混合式孤岛检测法。该混合法通过加入相位扰动来影响电网公共点相位和频率变化,以此变化来判断孤岛。理论分析与实验结果表明,该混合法能有效减小检测盲区,并且具有检测速度较快以及对电能质量影响较小的优点。 Due to the harm resulting from the phenomenon of islanding,it is necessary to perform islanding detection for the grid-connected photovoltaic system to guarantee its safe operation.First,the working principles of active phase shift based slip-mode frequency shift method and phase jump detection method are introduced,and their disadvantages in non-detection zones are analyzed.Then,from the aspect of phase,a mixed islanding detection method based on the combination of these two methods is proposed,with which the islanding can be judged by adding phase disturbance to affect the phase and frequency at the point of common coupling(PCC).The theoretical analysis and experimental results showed that this mixed method can effectively reduce the non-detection zone,and it had advantages of high detection speed and less influence on power quality.
作者 余运俊 王鹤官 范文奕 黄荟瑾 石晓凤 YU Yunjun;WANG Heguan;FAN Wenyi;HUANG Huijin;SHI Xiaofeng(School of Information Engineering,Nanchang University,Nanchang 330000,China)
出处 《电力系统及其自动化学报》 CSCD 北大核心 2018年第8期32-37,共6页 Proceedings of the CSU-EPSA
基金 国家自然科学基金资助项目(61563034) 国家国际科技合作专项资助项目(2014DFG72240) 江西省自然科学基金资助项目(20151BAB206051) 江西省2016年度百人远航工程 国家留学基金委资助项目(201508360100)
关键词 孤岛检测 滑模频率偏移法 相位突变检测法 光伏发电并网系统 islanding detection slip-mode frequency shift method phase jump detection method grid-connected photovoltaic system
  • 相关文献

参考文献10

二级参考文献90

共引文献176

同被引文献67

引证文献7

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部