摘要
农村低压配电网的接地型式是否合理将直接影响农村用电的安全性、可靠性等各项电能指标,选择农村低压配电网的接地型式应结合当地电网运行的实际、低压线路的健康状况,充分考虑区域的自然气候状况以及防雷与接地等各种因素。经分析,雷击少的北方地区的农村低压配电网易采用TT系统,经常遭受雷击、低压线路绝缘健康水平较高的南方地区更适宜采用TN-C-S系统。
Whether the rural LV power distribution network’s grounding type is reasonable or not can make a direct influence on rural electricity’s security and reliability,the selection of it should take a full account of regional natural climate conditions,lighting protection and other factors.After the analysis,northern area has less lighting,it should use TT system,Southern area has more lighting and a high line insulation health level,it should use TN-C-S system.
作者
刘石生
Liu Shisheng(China Southern Power Grid Company Limited,Guangdong power grid limited liability company Foshan Power Supply Bureau,Guangdong Foshan,528000)
出处
《现代科学仪器》
2018年第2期133-136,145,共5页
Modern Scientific Instruments
关键词
低压配电网
接地型式
差异化
选择策略
Low-voltage network
grounding type
differentiation
selection strategy