摘要
目的:探讨128排螺旋CT冠状动脉成像技术诊断冠状动脉狭窄的效果及应用价值。方法:选取2016年3月-2017年5月我院收治的88例疑似冠心病患者,均行128排螺旋CT冠状动脉成像(CTA)与冠状动脉造影(CAG)检查,将两种检查方法的诊断结果进行对比分析。结果:CTA检查对轻度狭窄的检出率为14.77%,与CAG检查结果相比差异显著(P<0.05),在中度狭窄、重度狭窄及闭塞中的检出率与CAG检查相似,差异无统计学意义(P<0.05)。CTA检查灵敏度为96.0%,特异度为78.57%。结论:128排螺旋CT冠状动脉成像技术在冠状动脉狭窄中的检查灵敏度、特异度与准确性较高,具有检查创伤小、操作简单的特点,临床应用价值较高。
Objective:To investigate the effect of 128-slice spiral CT coronary artery imaging in the diagnosis of coronary artery stenosis and its application value.Methods:Eighty-eight suspected coronary heart disease patients admitted to our hospital from March 2016 to May 2017 were selected for 128-slice spiral CT coronary artery imaging(CTA)and coronary angiography(CAG)examinations.Diagnostic results were compared and analyzed.Results:The detection rate of CTA was 14.77%for mild stenosis,which was significantly different from that of CAG(P<0.05).The detection rate in moderate stenosis,severe stenosis,and occlusion was similar to that of CAG.No statistical significance(P<0.05).The sensitivity of CTA examination was 96.0%and the specificity was 78.57%.Conclusion:The 128-slice spiral CT coronary artery imaging technique has higher detection sensitivity,specificity and accuracy in coronary artery stenosis.It has the characteristics of small examination,simple operation and high clinical value.
出处
《湖南中医药大学学报》
CAS
2018年第A01期1018-1019,共2页
Journal of Hunan University of Chinese Medicine