本文对太阳能辅助地源热泵复合系统进行数据监测,通过实验测试数据和分析地埋管循环液温度的变化特性以及地源热泵系统的效率,对已建立的地埋管换热器的传热模型进行验证,研究结果表明地源侧供水温度的理论计算值与实验测试值变化趋势一致,说明建立的地埋管传热模型是准确的。
This paper conducts data monitoring for the solar-assisted ground source heat pump system.The significant works were done to validate the established heat transfer model.The results show that the water supply temperatures of ground source side are in agreement with the experimental values,which means the established models are correct.
作者
孙长亮
李蕾
寇鹏
张文科
SUN Chang-liang;LI Lei;KOU Peng;ZHANG Wen-ke(Jinan Beilin Mechanical&Electrical Co.,Ltd.;School of Thermal Engineering,Shandong Jianzhu University;Samsung(China)Investment Co.,Ltd.)
出处
《建筑热能通风空调》
2018年第7期68-71,88,共5页
Building Energy & Environment
关键词
浅层地热能
太阳能
供回水温度
地源热泵系统
shallow geothermal energy
solar energy
supply and return water temperature
ground source heat pump