期刊文献+

基于空间直线约束的焊接机器人手眼标定 被引量:10

Hand-eye calibration of welding robot based on the constraint of spatial line
下载PDF
导出
摘要 视觉传感器与焊接机器人的标定是焊接智能化应用中的重要问题,针对末端夹持线结构光传感器的焊接机器人,提出了一种基于空间直线约束的手眼标定方法.首先任意变换机器人位姿使线结构光传感器投射出的光平面与标定模板相交,然后通过特征点提取算法提取出线结构光与直线的交点,并基于直线约束建立了非线性优化模型,最后结合罚函数法与改进的Powell算法同时求解传感器位置与方向参数.基于上述方法进行了一系列试验,结果表明,该方法通用性强,适合现场标定,有效的提高了标定精度,标定精度在0.2 mm以内. The calibration of vision sensor and welding robot is essential in the application of intelligent robot.In this article,to solve the hand-eye calibration of a welding robot holding a line structured light sensor,a method based on a spatial straight line is proposed.Firstly,the robot is required to manipulate randomly its end-effector so that the light plane projected by the line structured light sensor could intersect the calibration template at different configurations.Then the characteristic point extraction algorithm is used to extract the intersection point of the line structure light and the straight line.And a nonlinear optimization model is established based on the linear constraint.Finally,the penalty function method and the advanced Powell algorithm are used to solve the position and direction parameters simultaneously.Based on the above method,a series of experiments is carried out and the experimental results show that the method is versatile and suitable for on-site calibration,which effectively improves the calibration accuracy.The calibration accuracy is within 0.2 mm.
作者 郑健 张轲 罗志锋 王志刚 ZHENG Jian;ZHANG Ke;LUO Zhifeng;WANG Zhigang(Shanghai Key Laboratory of Materials Laser Processing and Modification,Shanghai Jiao Tong University,Shanghai 200240,China)
出处 《焊接学报》 EI CAS CSCD 北大核心 2018年第8期108-113,134,共7页 Transactions of The China Welding Institution
关键词 手眼标定 线结构光传感器 直线约束 hand-eye calibration line structured light sensor linear constraint
  • 相关文献

参考文献2

二级参考文献18

  • 1杨广林,孔令富,王洁.一种新的机器人手眼关系标定方法[J].机器人,2006,28(4):400-405. 被引量:34
  • 2王胜华,都东,张文增,陈强,邵家鑫.机器人定点变位姿手-眼标定方法[J].清华大学学报(自然科学版),2007,47(2):165-168. 被引量:21
  • 3Wang X G, Red E. Robotic TCF and rigid-body calibration methods[J]. Robotica, 1997, 15(6): 633-644.
  • 4Tsai R Y, Lenz R K. A new technique for fully autonomous and efficient 3D robotics hand/eye calibration[J]. IEEE Transactions on Robotics and Automation, 1989, 5(3): 345-358.
  • 5Shiu Y C, Ahmad S. Calibration of wrist-mounted robotic sen- sors by solving homogeneous transform equations of the form AX=XB[J]. IEEE Transactions on Robotics and Automation, 1989, 5(1): 16-29.
  • 6Park F C, Martin B J. Robot sensor calibration: Solving AX=XB on the Euclidean group[J]. IEEE Transactions on Robotics and Automation, 1994, 10(5): 717-721.
  • 7Zhuang H Q, Roth Z S, Sudhakar R. Simultaneous robot/world and tool/flange calibration by solving homogeneous transformation equations of the form AX=YB[J]. IEEE Transactions on Robotics and Automation, 1994, 10(4): 549-554.
  • 8Domaika F, Horaud R. Simultaneous robot-world and hand-eye calibration[J]. IEEE Transactions on Robotics and Automation, 1998, 14(4): 617-622.
  • 9Ma S D. A self-calibration technique for active vision systems[J]. IEEE Transactions on Robotics and Automation, 1996, 12(1): 114-120.
  • 10Zhang Z.A flexible new technique for camera calibration[J].IEEE Trans Pattern Analysis and Machine Intelligence,2000,22(11):1330-1334.

共引文献28