摘要 通过5根胶合木梁耐火极限试验,对三面受火胶合木梁的升温规律和耐火极限等进行了详细研究,主要考虑了截面尺寸和荷载比两个参数对其耐火极限的影响。研究结果表明:各测点温度随着受火时间的增加而升高,且停火之后温度下降较慢;测点离木截面表面距离越近,温度越高;且不同试件距边缘相同距离测点温度随时间的变化关系相差较小;相同截面的胶合木梁,随着荷载比的增加耐火极限减小;相同荷载比的胶合木梁,截面较小的木梁耐火极限较低。150 mm×300 mm截面胶合木梁荷载比为0.2、0.35和0.5时,耐火极限分别为46 min、33 min和25 min;而100 mm×200 mm截面胶合木梁荷载比为0.35时,耐火极限为18 min。 The temperature development and fire endurance of glulam beams exposed to three-side fire were carefully studied through the fire endurance test of five glulam beams.The effects of cross-section geometry and load ratio on their fire endurance were considered.Results showed that temperature increased with fire exposure time and decreased very slowly after the fire was stopped.The closer the thermocouples to the surface of glulam beam were,the higher their temperature was.Furthermore,for the thermocouples at different specimens with the same distance to the surface of glulam beam,temperature varied similarly with the fire exposure time.It was observed that for the glulam beams with the same geometry,the fire endurance decreased with load ratios,while for the glulam beams subjected to the same load ratios,the fire endurance decreased with geometry.The fire endurance of glulam beams with the 150 mm×300 mm cross-section tested under the load ratio of 0.2,0.35 and 0.5 were 46 min,33 min and 25 min respectively,while the fire endurance of glulam beams with the 100 mm×200 mm cross-section tested under the load ratio of 0.35 was 18 min.
作者 陈玲珠 许清风 王欣 CHEN Lingzhu;XU Qingfeng;WANG Xin(Shanghai Key Laboratory of Engineering Structure Safety,Shanghai Research Institute of Building Sciences,Shanghai 200032,China;University of Shanghai for Science and Technology,Shanghai 200093,China)
出处 《结构工程师》 北大核心 2018年第4期109-116,共8页 Structural Engineers
基金 上海市青年科技启明星计划项目(17QB1403400) 上海市科委课题(17DZ1203702)
关键词 胶合木梁 三面受火 耐火极限 跨中挠度 glulam beam three-side fire fire endurance mid-span deflection
  • 相关文献

参考文献4

二级参考文献50

  • 1GB50005-2003木结构设计规范[S].北京:中国建筑工业出版社,2006.
  • 2GB50016—2006建筑设计防火规范[S].北京:中国计划出版社,2006.
  • 3GB/T50361--2005木骨架组合墙体技术规范[S].北京:中国计划出版社,2006.
  • 4DG/TJ08-2059--2009轻型木结构建筑技术规程[S].上海,2009.
  • 5GB/T50708--2012胶合木结构技术规范[S].北京:中国建筑工业出版社,2012.
  • 6ISO 834-1 : 1999 Fire resistance tests--Elements of building construction. Part 1 : General requirements [ S ]. Switzerland : Interuational Organization for Standardization, 1999.
  • 7ASTM Ell9 Standard methods of fire tests of building constructions and materials [ S ]. West Conshohochen, PA: American Society for Testing and Materials, 2007.
  • 8Sultan M A, Lougheed G D. Resuhs of fire resistance tests on full-scale gypsum board wall assemblies [ R ]. Ottawa, Canada: Institute for Research in Construction, National Research Council of Canada, 2002.
  • 9Sultan M A, Seguin Y P, Leroux P. Results of fire resistance tests on full-scale floor assemblies [ R]. Ottawa, Canada: Institute for Research in Construction, National Research Council of Canada, 1998.
  • 10Konig J, Noren J, Olesen F B, et al. Timber frame assemblies exposed to standard and parametric fires-Part 1: fire tests[ R]. Stockholm, Sweden: Swedish Institute of Wood Technology, 1997.