摘要 为评定欧盟空气源热泵热水器(静态)机组参考放水循环总有效热能的测量不确定度,对其参考放水循环测试过程进行分析,建立测量不确定度评定的数学模型,确定其测量不确定度的主要来源为水体积流量的测量。分析结果表明,水体积流量计的测量精度对测量不确定度贡献值最大,占总有效热能测量不确定度的90%左右,是直接影响测量结果不确定度的主要因素;进、出水温度测量精度对总测量不确定度的影响次之;重复性测量导致的不确定度对总测量不确定度的影响只有0.1%左右,基本可忽略不计。 In order to evaluate the measurement uncertainty in total effective heat of the air-source heat pump water heater(static)of European Union in the reference drain cycle,its reference water drainage cycle test process was analyzed,and a mathematical model for evaluating the measurement uncertainty was built,and it was determined that the main source of its measurement uncertainty was the measurement of water volume flow.The analysis results show that the measurement accuracy of the water volume flowmeter has the largest contribution to the total measurement uncertainty,accounting for about 90%of the total measurement uncertainty of total effective heat,which is the main factor affecting the measurement uncertainty.The second influencing factor is the measurement accuracy of the inlet and outlet water temperature.The effect of uncertainty caused by repeatability measurement on the total measurement uncertainty is only about 0.1%,which is basically negligible.
作者 杨华 张威 何林 YANG Hua;ZHANG Wei;HE Lin(State Key Lab of Air-conditioning Equipment and System Energy Conservation,Zhuhai 519070,China)
出处 《流体机械》 CSCD 北大核心 2018年第9期80-83,共4页 Fluid Machinery
关键词 测量不确定度 总有效热能 参考放水循环 热泵热水器(静态)机组 measurement uncertainty total effective heat energy reference drain cycle air source heat pump water heater(static)unit
  • 相关文献

参考文献5

二级参考文献17

  • 1田旭东,周仝,张宝怀,史敏.制冷压缩机制冷量的测定及其不确定度分析[J].流体机械,2004,32(9):69-72. 被引量:19
  • 2王海民,蒋旭平,唐恒.汽车空调制冷量测量不确定度分析[J].计量与测试技术,2004,31(8):40-41. 被引量:6
  • 3JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 4上海市计量测试技术研究院.常用测量仪器测量不确定度评定案例[M].北京:中国计量出版社,2001.34-36,62-65.
  • 5Guide to the Expression of Uncertainty in Measurement[S].Geneva: International Organization for Standardization. Corrected and reprinted, 1995.
  • 6Grabe M. Estimation of measurement uncertainty - an alternative to the ISO Guide[J]. Metrologia, 2001, 38(2) :97~ 106.
  • 7陈奕钦.测量不确定度93国际指南应用实例[M].北京:中国计量出版社,1993..
  • 8李慎安 施昌彦 刘风.JJF1059-1999测量不确定度评定与表示[S].北京:中国计量出版社,1999..
  • 9宣湘.测量不确定度评定与表示实例[M].北京:中国计量出版社,2001..
  • 10.JJG165-1989,钟罩式气体流量标准装置检定规程[S].北京:中国计量出版社,1990..

共引文献34

同被引文献14

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部