摘要
将尼龙66聚合物用甲酸溶解、真空过滤、清洗、烘干后得到凝胶,再溶于浓硫酸中制得凝胶硫酸溶液,采用紫外可见分光光度法测定凝胶含量,并与常规甲酸萃取法进行比较。结果表明:常规甲酸萃取法测定结果误差较大,其相对偏差为16. 1%~22. 8%;用紫外可见分光光度法,在波长为199. 5 nm处测定尼龙66聚合物中凝胶含量,其测定误差较小,加标回收率为99. 00%~100. 95%,相对标准偏差为0. 035%~0. 15%,方法的准确度和重复性较好。
Gel was obtained from nylon 66 after dissolving in formic acid,vacuum filtration,washing and drying processes and was dissolved in sulfuric acid to produce a gel sulfuric acid solution.The ultraviolet-visible spectrophotometry determination of gel content was performed and compared with traditional formic acid extraction method.The results showed that the ultraviolet-visible spectrophotometry determination had fairly good accuracy and repeatability with a minor measuring error at the wavelength of 199.5 nm,the recovery of standard addition of 99.00%-100.95%and the relative standard deviation of 0.035%-0.15%when the traditional formic acid extraction method had large measurement error and the relative deviation of 16.1%-22.8%.
作者
王安乐
Wang Anle(Shenma Industrial Co.,Ltd.,China Pingmei Shenma Group,Pingdingshan 467000)
出处
《合成纤维工业》
CAS
2018年第5期76-79,共4页
China Synthetic Fiber Industry
关键词
聚己二酰己二胺
凝胶
紫外可见分光光度法
甲酸
硫酸
萃取
吸光度
polyhexamethylene adipamide
gel
ultraviolet-visible spectrophotometry
formic acid
sulfuric acid
extraction
absorbance