宁波轨道交通3号线采用LTE(长期演进)综合承载信号系统和专用无线系统。为了确保方案的可靠性,对LTE设备供电方案进行了优化加强。在非集中站,采用了双套UPS(不间断电源)输出双母线的方案;采用蓄电池供电分时下电,满足不同的UPS供电时间要求;对正线及OCC(运营控制中心)的所有LTE设备,经过计算分析,采用综合供电方案。
Ningbo rail transit Line 3 adopts LTE integrated bearer signal system and the dedicated wireless system.To ensure the reliability,the power supply solution for LTE equipment is optimized and strengthened.At the decentralized stations,a dual UPS and output double bus set is adopted,which uses battery time-sharing TOU power down to satisfy the time requirements for different UPS power supply.For the positive line and all LTE devices in OCC(operating control center),the integrated power supply plan is adopted through calculation and analysis.
作者
朵建华
DUO Jianhua(Ningbo Rail Transit Group Co.,Ltd.,315101,Ningbo,China)
出处
《城市轨道交通研究》
北大核心
2018年第10期123-127,共5页
Urban Mass Transit
关键词
宁波轨道交通3号线
信号系统
不间断电源
分时下电
综合供电
Ningbo urban rail transit Line 3
signal system
uninterrupted power supply(UPS)
TOU(time-of-use)power down
integrated power supply