摘要 AIM To determine the influence of the construction design over the biological component's performance in an experimental bio-artificial liver(BAL) device.METHODS Two BAL models for liver microorgans(LMOs) were constructed. First, we constructed a cylindrical BAL and tested it without the biological component to establish its correct functioning. Samples of blood and biological compartment(BC) fluid were taken after 0, 60, and 120 min of perfusion. Osmolality, hematocrit, ammonia and glucose concentrations, lactate dehydrogenase(LDH) release(as a LMO viability parameter), and oxygen consumption and ammonia metabolizing capacity(as LMO functionality parameters) were determined. CPSI and OTC gene expression and function were measured. The second BAL, a "flat bottom" model, was constructed using a 25 cm2 culture flask while maintaining all other components between the models. The BC of both BALs had the same capacity(approximately 50 cm3) and both were manipulated with the same perfusion system. The performances of the two BALs were compared to show the influence of architecture.RESULTS The cylindrical BAL showed a good exchange of fluids and metabolites between blood and the BC, reflected by the matching of osmolalities, and glucose and ammonia concentration ratios after 120 min of perfusion. No hemoconcentration was detected, the hematocrit levels remained stable during the whole study, and the minimal percentage of hemolysis(0.65% ± 0.10%) observed was due to the action of the peristaltic pump. When LMOs were used as biological component of this BAL they showed similar values to the ones obtained in a Normothermic Reoxygenation System(NRS) for almost all the parameters assayed. After 120 min, the results obtained were: LDH release(%): 14.7 ± 3.1 in the BAL and 15.5 ± 3.2 in the NRS(n = 6); oxygen consumption(μmol/min?g wet tissue): 1.16 ± 0.21 in the BAL and 0.84 ± 0.15 in the NRS(n = 6); relative expression of Cps1 and Otc: 0.63 ± 0.12 and 0.67 ± 0.20, respectively, in the BAL, and 0.86 ± 0.10 and 0.82 ± 0.07, respectively, in the NRS(n = 3); enzymatic activity of CPSI and OTC(U/g wet tissue): 3.03 ± 0.86 and 222.0 ± 23.5, respectively, in the BAL, and 3.12 ± 0.73 and 228.8 ± 32.8, respectively, in the NRS(n = 3). In spite of these similarities, LMOs as a biological component of the cylindrical BAL were not able to detoxify ammonia at a significant level(not detected vs 35.1% ± 7.0% of the initial 1 mM NH4+ dose in NRS, n = 6). Therefore, we built a second BAL with an entirely different design that offers a flat base BC. When LMOs were placed in this "flat bottom"device they were able to detoxify 49.3% ± 8.8% of the initial ammonia overload after 120 min of perfusion(n = 6), with a detoxification capacity of 13.2 ± 2.2 μmol/g wet tissue.CONCLUSION In this work, we demonstrate the importance of adapting the BAL architecture to the biological component characteristics to obtain an adequate BAL performance. AIM To determine the influence of the construction design over the biological component's performance in an experimental bio-artificial liver(BAL) device.METHODS Two BAL models for liver microorgans(LMOs) were constructed. First, we constructed a cylindrical BAL and tested it without the biological component to establish its correct functioning. Samples of blood and biological compartment(BC) fluid were taken after 0, 60, and 120 min of perfusion. Osmolality, hematocrit, ammonia and glucose concentrations, lactate dehydrogenase(LDH) release(as a LMO viability parameter), and oxygen consumption and ammonia metabolizing capacity(as LMO functionality parameters) were determined. CPSI and OTC gene expression and function were measured. The second BAL, a "flat bottom" model, was constructed using a 25 cm2 culture flask while maintaining all other components between the models. The BC of both BALs had the same capacity(approximately 50 cm3) and both were manipulated with the same perfusion system. The performances of the two BALs were compared to show the influence of architecture.RESULTS The cylindrical BAL showed a good exchange of fluids and metabolites between blood and the BC, reflected by the matching of osmolalities, and glucose and ammonia concentration ratios after 120 min of perfusion. No hemoconcentration was detected, the hematocrit levels remained stable during the whole study, and the minimal percentage of hemolysis(0.65% ± 0.10%) observed was due to the action of the peristaltic pump. When LMOs were used as biological component of this BAL they showed similar values to the ones obtained in a Normothermic Reoxygenation System(NRS) for almost all the parameters assayed. After 120 min, the results obtained were: LDH release(%): 14.7 ± 3.1 in the BAL and 15.5 ± 3.2 in the NRS(n = 6); oxygen consumption(μmol/min?g wet tissue): 1.16 ± 0.21 in the BAL and 0.84 ± 0.15 in the NRS(n = 6); relative expression of Cps1 and Otc: 0.63 ± 0.12 and 0.67 ± 0.20, respectively, in the BAL, and 0.86 ± 0.10 and 0.82 ± 0.07, respectively, in the NRS(n = 3); enzymatic activity of CPSI and OTC(U/g wet tissue): 3.03 ± 0.86 and 222.0 ± 23.5, respectively, in the BAL, and 3.12 ± 0.73 and 228.8 ± 32.8, respectively, in the NRS(n = 3). In spite of these similarities, LMOs as a biological component of the cylindrical BAL were not able to detoxify ammonia at a significant level(not detected vs 35.1% ± 7.0% of the initial 1 mM NH4+ dose in NRS, n = 6). Therefore, we built a second BAL with an entirely different design that offers a flat base BC. When LMOs were placed in this "flat bottom"device they were able to detoxify 49.3% ± 8.8% of the initial ammonia overload after 120 min of perfusion(n = 6), with a detoxification capacity of 13.2 ± 2.2 μmol/g wet tissue.CONCLUSION In this work, we demonstrate the importance of adapting the BAL architecture to the biological component characteristics to obtain an adequate BAL performance.
出处 《World Journal of Hepatology》 CAS 2018年第10期719-730,共12页 世界肝病学杂志(英文版)(电子版)
基金 Supported by Universidad Nacional de Rosario(UNR),BIO 272,Resol.C.S.,No.677/2013 Agencia Nacional de Promoción Científica y Tecnológica(ANPCyT),PICT-03-14492,BID 1728 OC/AR(Argentina) a grant from Regione Autonoma FriuliVenezia Giulia,Italy
关键词 Bio-artificial LIVER AMMONIA DETOXIFICATION Device design ORNITHINE Transcarbamylase Rat LIVER microorgans Carbamyl Phosphate SynthetaseⅠ Bio-artificial liver Ammonia detoxification Device design Ornithine Transcarbamylase Rat liver microorgans Carbamyl Phosphate Synthetase Ⅰ
  • 相关文献

参考文献2

二级参考文献3

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部